Brochure

Technical data
44
TM03 5574 0907
0 2 4 6 8 10 12 14 16 18
Q [US GPM]
0
2
4
6
8
10
12
14
16
[ft]
H
3
2
1
Flow range: 0-17.5 U.S. gpm
Head range: 0-15.5 feet
Motors: 2-pole, single-phase
Max. liquid temperature: 230 °F (110 °C)
Min. liquid temperature: 36 °F (2 °C)
Max. system pressure: 145 psi
Model Spd Volts Amps Watts Hp Capacitor
UPS 15-42F/FR
3
115
0.74 85 1/25 10μF/180 V
20.5765--
10.445--
UPS 15-42F
3
230
0.41 92 1/25 2μF/400 V
20.1940--
10.1430--
Position System type Description
1 Closed Low speed
2 Closed Medium speed
3 Closed High speed
UPS 15-42F UPS 15-42FR
TM03 8757 2407
TM03 9035 2407
Model type
Product number
ABCDEF
Connection type
and size
Shipping weight
[lbs]
115 V 230 V
UPS 15-42F 59896315 59896180 6 1/2 5 1/4 4 4 3/16 3 1/4 3 5/32
GF 15/26 flange
(2) 1/2" dia. bolt boles
7 1/4
UPS 15-42FR 59896250 - 6 1/2 5 15/16 4 3 3/4 3 1/4 3 5/32 7 1/4
UP Series
UPS 15-42F/FR
UPSeries.book Page 44 Tuesday, September 18, 2007 1:01 PM