Brochure

Technical data
47
Super Brute
Note: The check valve can be removed.
TM03 5535 0907
0 2 4 6 8 10 12 14 16 18 20
Q [US GPM]
0
2
4
6
8
10
12
14
16
18
20
[ft]
H
1
2
3
Flow range: 0-17 U.S. gpm
Head range: 0-19.5 feet
Motors: 2-pole, single-phase
Max. liquid temperature: 230 °F (110 °C)
Min. liquid temperature: 36 °F (2 °C)
Max. system pressure: 145 psi
Model Spd Volts Amps Watts Hp Capacitor
UPS 15-58FC/FRC
3
115
0.75 87 1/25 10μF/180 V
2 0.66 80 1/25 10μF/180 V
1 0.55 60 1/25 10μF/180 V
Without check valve
With check valve
Position System type Description
3 Closed High speed
2 Closed Medium speed
1 Closed Low speed
UPS 15-58FC UPS 15-58FRC
TM03 8757 2407
TM03 8531 1907
Model type Product number A B C D E F
Connection type
and size
Shipping weight
[lbs]
UPS 15-58FC 59896341 6 1/2 5 1/4 4 4 3/16 3 3 5/32
GF 15/26 flange
(2) 1/2" dia. bolt boles
7 1/4
UPS 15-58FRC 59896343 6 1/2 5 1/4 4 4 3/16 3 3 5/32
GF 15/26 flange
(2) 1/2" dia. bolt boles
7 1/4
UP Series
UPS 15-58FC/FRC
UPSeries.book Page 47 Tuesday, September 18, 2007 1:01 PM