Brochure

Technical data
65
\
Note: Dimensions in inches unless otherwise noted.
TM04 5464
UPS 43-100 F/SF
TM04 6015
1
2
3
B
C
A
D
F
E
Flow range: 0-65 gpm
Head range: 0-31 feet
Motors: 2-pole, single-phase
Max. liquid temperature: 230 °F (110 °C)
Min. liquid temperature: 36 °F (2 °C)
Max. system pressure: 145 psi (10 bar)
Model Spd Volts Amps Watts Hp Capacitor
UPS 43-100 F/SF
3
115
3.5 370 1/6 40μF/180 V
2 3.1 335 1/6 40μF/180 V
1 2.5 265 1/6 40μF/180 V
3
208
1.7 350 1/6 10μF/400 V
2 1.5 310 1/6 10μF/400 V
1 1.2 250 1/6 10μF/400 V
3
230
1.7 370 1/6 10μF/400 V
2 1.5 335 1/6 10μF/400 V
1 1.2 265 1/6 10μF/400 V
Approvals
Model type
Product number Dimensions [inches]
Connection type
and size
Shipping weight
[lbs]
115 V 208 - 230 V A B C D E F
UPS 43-100 F 95906636 95906637
8 1/2 7 3/8 5 7/8 4 1/2 3 3/4 3 1/8
GF 40/43 flange
(2) 1/2" dia. bolt boles
18.47
UPS 43-100 SF 95906638 95906639
GF 40/43 flange
(2) 1/2" dia. bolt boles
18.47
UPS 43-100 F/SF