Brochure

Table Of Contents
Applications
UP Series
5
37
UP 10 Comfort pump
Water flowing through the pump is hermetically
separated from the stator with a stainless steel
spherical separator. The motor can be separated from
the pump housing, enabling easy maintenance and
replacement.
Applications
Domestic hot-water recirculation systems in single-
and two-family houses
small heating systems.
Pumped liquids
Domestic hot water
non-potable water
softened water.
Fig. 9 Comfort pump
Fig. 10 Comfort pump
Motor
Insulation class: F
power consumption: 25 W
voltage: 115 V
phase: 1.
Ambient and liquid temperatures
Liquid temperature: 36 °F (2 °C) to 203 °F (95 °C).
It is recommended to keep the operating temperature
as low as possible (e.g. 140 °F (60 °C)) to avoid
calcium precipitation.
The ambient temperature should always be lower than
the liquid temperature, as otherwise condensation may
form in the stator housing.
Maximum system pressure
145 psi (10 bar).
Inlet pressure
To avoid cavitation noise and damage to the pump
bearing at high temperatures, the following minimum
pressures are required at the pump suction port.
Features and options:
24-hour timer (15 minute increments)
continuous ON, OFF
models with adustable aquastat
95 °F (35 °C) 150 °F (65 °C).
TM05 7098 0513TM04 9805 0111
Description Material
Stator housing Aluminium
Spherical separator Stainless steel
Rotor can complete Stainless steel/tungsten carbide
Rotor, impeller
Stainless steel, EPDM, PPO,
PFTE, graphite
Pump housing Brass MS 58
Isolating valve PPO
Screw Stainless steel
Terminal box cover, motor cover PA66/6
Light Lexan
Cable, cable relief PVC
Insulating cover EPP 55
O-rings EPDM
Check valve POM
Liquid temperature
203 °F
(95 °C)
185 °F
(85 °C)
Inlet pressure
9 ft
(2.8 m)
1.6 ft
(0.5 m)
4.0 psi
(0.3 bar)
0.7 psi
(0.05 bar)