User Guide
11
(QJOLVK86
9.2 Control panel
The control panel, fig. 11, incorporates:
For further information, see section
10. Troubleshooting.
Fig. 11 Control panel
9.2.1 Control mode setting
Description of function, see section 8.4 Control
modes.
To change the control mode, press , pos. 3,
according to this cycle:
Fig. 12 Cycle of control modes
Automatic nighttime duty can be activated together
with each of the control modes.
The light symbols in pos. 4 of fig. 11, indicate the
pump settings:
"–" = no light.
Warning
At high liquid temperatures, the
pump may be so hot that only the
buttons should be touched to avoid
burns.
Pos. Description
1 Buttons for setting
2
• Indicator lights for operating and
fault indication and
• symbol for indication of external con-
trol
3 Button for change of control mode
4
Light symbols for indication of control
mode and night-time duty
5
Light fields for indication of head, flow
and operating mode
TM03 8752 2407
TM03 1288 1505
Light in Control mode
Automatic
nighttime
duty
AUTO
ADAPT AUTOADAPT NO
Proportional
pressure
NO
Constant
pressure
NO
– Constant curve NO
AUTO
ADAPT
AUTOADAPT YES
Proportional
pressure
YES
Constant
pressure
YES
– Constant curve YES