Brochure

Table Of Contents
Technical data
UP Series
6
57
UP variable speed
UP 15-42 F/VS
Approvals
Variable speed models include the following
features:
Three speed-control options:
1. Manual
2. Voltage: 0-10 V(DC) or 2-10 V(DC)
3. Current: 0-20 mA or 4-20 mA
DIP switch control selection
pump exercising
manual offset dial
performance indicator LED's.
Note: Dimensions in inches unless otherwise noted.
TM03 8840 4412
UP 15-42 F/VS
TM03 8528 1907
0 2 4 6 8 10 12 14 Q [US GPM]
0
2
4
6
8
10
12
14
16
[ft]
H
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Q [m³/h]
0
1
2
3
4
5
[m]
H
a. MIN - UP15-42F/FV
b. MAX - UP15-42F/FV
60 Hz
b
a
Flow range: 0-16 gpm (0 - 3.6 m
3
/h)
Head range: 0 - 15.5 ft (0 - 4.7 m)
Motors: 2-pole, single-phase
Max. liquid temperature: 205 °F (96 °C)
Min. liquid temperature: 36 °F (2 °C)
Max. system pressure: 145 psi (10 bar)
Model Volts Amps Watts Hp Capacitor
UP 15-42 F/FV 115 0.74 85 1/25 10 F/180 V
Model
Product
number
115 V
Dimensions [inches (mm)]
Connection type and
size
Shipping weight
[lbs (kg)]
ABCDEF
UP 15-42 F/VS 59896807 6.50 (165) 5.25 (133) 4.00 (102) 4.19 (106) 3.25 (83) 3.16 (80)
GF 15/26 flange
(2) 1/2" dia. bolt holes
7.5 (3.4)