AGS Algorithm description
Oscillation can be reduced in case that 3dB Attenuation is increased in an excess of Isolation Gap
ATT status value : 0~2.5dB (Shutdown on , DL/UL PAM on, DL Always OSC on)
3dB~30dB (ALC on ,shutdown on , DL/UL PAM on, DL Always OSC on)
Over 30dB (uplink OSC Alarm , DL/UL PAM off )
References
1. Isolation Check in initial set up or Reset
2. Monitoring Oscillation comparing to minimum/maximum Noise Floor level
3. When Oscillation occurred, repeater attempts to stabilize Isolation through Gain control function
4. Shutdown repeater when Oscillation still occurs in Minimum Gain
5. Automatic Recovery Algorithm conversion after Shutdown status
Isolation Gap
ATT: 3dB
Max ATT (30dB)
Shutdown on ,DL/UL PAM on
DL Always OSC on
3dB Attenuation will be increased in an access of Isolation Gap
ALC on , shutdown on ,DL/UL PAM on
DL Always OSC on
Uplink OSC Alarm
DL/UL PAM OFF
isolation Gap value Comparison of
isolation Gap value status and reduced
by ATT 3dB