4.2. ICS General Performance
No.
Parameter
Condition
Specification
1
Gain Re-Tracking Time after reset
Target Gain ±1dB
< 10 Sec
2
Isolation Sensing Range
-10dB < Gain < 10dB
-20dB < Gain < 20dB
Accuracy ±1
Accuracy ±3
3
G = I + 15dB
Static
General Operating
4
G = I
10Hz
Fast Fading
Table 4. GST-IC-ELITE-1943 ICS General Performance
4.3. Frequency Information
4.3.1. CDMA Band CLASS 1
Block
Transmit frequency band (MHz)
Bandwidth
UL / DL
Uplink
Downlink
A
1850
1865
1930
1945
15
D
1865
1870
1945
1950
5
B
1870
1885
1950
1965
15
E
1885
1890
1965
1970
5
F
1890
1895
1970
1975
5
C
1895
1910
1975
1990
15
Table 5. GST-IC-ELITE-1943 Operation Band for CDMA Band Class 1
4.3.2. LTE Band 25
BW
ERAFCN (Count 1 step)
Center Frequency (100KHz step)
Start
Stop
Start(MHz)
Stop(MHz)
5MHz
8065
8665
1932.5
1992.5
10MHz
8090
8640
1935
1990