User Manual

SPRINT User Manual
iDEN 30dBm
12
@CH offset 2 MHz
> 55 dBm
@ Degradation of 3dB for eight iDEN carriers
@ 869 MHz 868.8MHz/868.6MHz Adjust
Band Edge
@ 940 MHz 939.8MHz/939.6MHz
Band Select Local Shift & RF Switching
Roll Offs > 50dBc
3.2 Electrical and Environment Specifications
Items specification
Size(mm) / Type 16(W)*18(L)*7(H) / Inch
Power AC 120V 60Hz 3.0A
Temperature / Weight
0 ~ +50/20.6kg
Connector TYPE N Type Female
3.3 Functions
Parameter Specification
Gain Control
• Adjustable DL and UL Gain range 55~80dB
• Display default Gain and current Gain function
AGC
Auto Gain Control
• It always operates in Downlink AGC ON status
• To maintain same Downlink output power despite flexible input signal
strength.
• To add or subtract Attenuation level referring to AGC Power Limit level.
ALC
Auto Limit Control
• To limit output power as far as default range
• Set up via GUI
• Automatic Gain decrement when output power of repeater is higher than
default level
• Automatic Gain recovery when output power of repeater is reduced.
• Shutdown when output power is higher than default level in Minimum Gain
• Automatic Recovery Algorithm conversion after Shutdown status
Band Select
• In case of 800MHz FWD Band, it enables User to select one of 18MHz,
17.8MHz, 17.6MHz/ 7MHz, 6.8MHz, and 6.6MHz according to GUI setting.
• In case of 900MHz FWD Band, it enables User to select one of 5MHz,
4.8MHz, 4.6MHz according to GUI setting.
• In case of 800MHz RVS Band, it enables User to select one of 18MHz/
7MHz according to GUI setting.