User Manual
SPRINT User Manual 
iDEN 30dBm 
 13
• In case of 900MHz RVS Band, it enables User to select 5MHz according to 
GUI setting. 
Band Edge Adjust  • To shift Band edge of DL high frequency side by 200kHz, 400kHz step 
 Power Monitoring 
Function 
• Monitoring repeater’s output level 
Oscillation Check 
• Isolation Check in initial set up or Reset 
• Monitoring Oscillation comparing to minimum/maximum Noise Floor level 
• When Oscillation occurred, repeater attempts to stabilize Isolation through 
Gain control function. 
• Shutdown repeater when Oscillation still goes in Minimum Gain 
• Automatic Recovery Algorithm conversion after Shutdown status 
DL Input control  • Monitoring Donor ANT input power of DL 
Automatic Recovery 
• When in repeater shutdown, it periodically recovers output power of 
repeater then monitors alarming 
Security 
• Support HTTPS for Web Browser security 
• User authentication through User ID and Password 
Temperature 
control 
• Monitoring temperature of repeater 
• Maximum and minimum set up is possible. Shutdown in over temperature 
• Automatic recovery after temperature becomes normal. (Hysteresis 
10degree) 
VSWR Monitoring 
• Monitoring VSWR of Donor ANT Port (Every one and half minute) 
• Reporting VSWR Alarm and Shutdown when the rate is 3:1 
• Automatic Recovery Algorithm conversion after Shutdown status 
IP address report 
via E-mail 
• When in PPP reconnection, E-mail which includes HTML to connect to 
newly assigned IP Address, reports to operator. 
DHCP Client  • Automatic IP assignment 
DHCP Server  • Server function for automatic IP assignment 
Web GUI  • Remote and local user browser support through Web Browser 
SNMP Agent  • NMS report via SNMPv2 Trap 
LED Display 
• LED displays power and operation status on front side of repeater system. 
• DL input and output signal level is verified by LED bar. 