4. SET UP 
4.1 System Set up 
4.1.1 Constitution (based on 1 SET) 
Parameter  Item  Quantity Remark 
Major accessory  CDMA 30dBm repeater  1 EA  Manufacture company supply 
Additional 
components 
Ethernet Cable (cross) 
Power Supply Cable 
Fixable Screw x 4 (Size: φ1/2”, 
length: 2” ) 
Ground Cable 
CD which contains User Manual 
and installation Guide 
1 EA 
1 EA 
1 SET 
1 EA 
1 EA 
Manufacture company supply 
User Manual  Installation Guide (Book)  1 EA  Manufacture company supply 
Antenna 
Donor ANT 
Server ANT 
1EA 
1EA 
Establishment construction company 
 preparation 
RF Cable  Antenna connection Cable  TBD 
Establishment construction company 
 preparation 
Repeater quality 
confirmation 
equipment 
Spectrum Analyzer  1EA 
Establishment construction company 
 preparation 
4.1.2 Notice 
1) System Power check: Major electricity is AC110V, therefore please input electricity after power 
verification. 
2) Input condition optimization: DL input condition is -56 ~ -16dBm. User should verify input condition of 
Donor ANT. 
3) Isolation check between DONOR/SERVICE ANT: Isolation condition of this equipment is 95dBc (Gain+
15dB). User should check its condition before installation. 
Report No. : HCT-R07-013     15/33 