When in 
alarming 
* DL over-input alarm 
* Please Check following status 
- Proper maximum output power limit level 
- BTS input level (Spectrum Level) 
- Input RSSI value at Status mode 
- Downlink Attenuation level 
- Downlink Attenuation Table 
* Please reset AC power upon complete Alarm trouble shooting
When in 
alarming 
* DL over-output alarm 
* Please make sure output power is operated normally. 
* Please reset AC power upon complete Alarm trouble 
shooting. 
When in 
alarming 
* UL over-output alarm 
* Please make sure output level is operated normally 
* Please reset AC power upon complete Alarm trouble shooting
When in 
alarming 
* VSWR alarm 
* Please Check following status 
- Antenna port connection 
- Whether inner-output cable is damaged or not. 
 * Please reset AC power upon complete Alarm trouble 
shooting 
When in 
alarming 
* IF Module alarm 
* Please verify IF Module LED is On. 
* When LED is Off, module should be defective. 
When in 
alarming 
* DL, UL PAM alarm 
* Please reset AC power upon complete Alarm trouble shooting
When in 
alarming  * DC matter/Current alarm 
* Please verify DC power by using DVM (Digital Voltage Meter) 
* Please reset AC power upon complete Alarm trouble 
shooting. 
When in 
alarming * UL Oscillation 
* Please check Isolation between Donor and Server. 
* Please reset AC power upon complete Alarm trouble 
shooting. 
When in 
alarming 
* DL / UL LNA alarm 
* Please check connection status of LNA. 
* Please reset AC power upon complete Alarm trouble shooting
Report No. : HCT-R07-013     21/33 