User's Manual

Version
1.1
Date
January 28th, 2019
Page
22/ 49
Title
USER MANUAL
Prepared by
Reviewed by
Approved by
© 2019 GS Teletech Inc. All rights reserved
6. Status/ Control & Alarm Monitoring
6.1. Status Monitoring and Control Parameters
In case of control parameter, present status but also setting value display on Web-UI.
Parameter
Status
Control
Description
Downlink
RSSI
DL Input Power Display
Output
DL Output Power Display
System Gain
DL System Gain Display
ALC
Set the ALC function On/Off
ALC Low Limit
Set the ALC Low Limit Value
Path On/Off
Decide to cut off to LTE or NR
Attenuation
In order to adjust system gain,
set the attenuation value
Isolation (Unit: dB)
Display the isolation value between
Donor antenna and Service antenna
Band Selection
Select the band that user want to operate
Final AMP
Set the High Power final AMP On/Off
ASD
Set the Auto Shutdown function On/Off
Uplink
RSSI
UL Input Power Display
Output
UL Output Power Display
System Gain
UL System Gain Display
ALC
Set the UL ALC function On/Off
Path On/Off
Decide to cut off LTE or NR
Attenuation
In order to adjust system gain,
set the attenuation value
Isolation (Unit: dB)
Display the isolation value between
Donor antenna and Service antenna
Gain Balance
Select the band that user want to operate
& Set the Offset Value
Final AMP
Set the High Power final AMP On/Off
ASD
Set the Auto Shutdown function On/Off
Common
Site ID
Write the location Info. that install a repeater