Version Date 1.0 Title NOV. 27, 2018 Prepared by USER MANUAL Reviewed by Page 1/ 42 Approved by KO. SUNGMOO USER MANUAL PSD-LI27 PSS-LI33 / PSS-LI37 NOV. 27, 2018 GS Instech Co., Ltd. 1 © 2018 GS Instech Co., Ltd. All rights reserved.
Version Date 1.0 Title NOV. 27, 2018 Prepared by USER MANUAL Reviewed by Page 2/ 42 Approved by KO. SUNGMOO [CHANGE RECORD] DATE NAMES DESCRIPTIONS VERSION NOV 17, 2018 KO. SUNGMOO Original Draft 1.0 DEC 27, 2018 KO. SUNGMOO Add Label Information 1.1 2 © 2018 GS Instech Co., Ltd. All rights reserved.
Version Date 1.0 Title USER MANUAL NOV. 27, 2018 Prepared by Reviewed by Page 3/ 42 Approved by KO. SUNGMOO [TABLE OF CONTENTS] CHAPTER’s INDEX 1. GENERAL ...........................................................................................................................................6 1.1. Purpose .............................................................................................................................................6 1.2. Copyright ....................................
Version Date 1.0 Title NOV. 27, 2018 Prepared by USER MANUAL Reviewed by Page 4/ 42 Approved by KO. SUNGMOO 7. SYSTEM BLOCK CONFIGURATION ...................................................................................................29 7.1. Block Diagram .................................................................................................................................29 8. GUI OVERVIEW ................................................................................................
Version Date 1.0 Title USER MANUAL NOV. 27, 2018 Prepared by Reviewed by Page 5/ 42 Approved by KO. SUNGMOO FIGURE 12. SYSTEM BLOCK DIAGRAM ...................................................................................................................................................................... 25 FIGURE 13. 700MHZ BAND ALLOCATION ................................................................................................................................................................
Version Date 1.0 Title NOV. 27, 2018 Prepared by USER MANUAL Reviewed by Page 6/ 42 Approved by KO. SUNGMOO General 1. 1.1. Purpose This document introduces features, specifications, structures and operation guideline for the PSD-LI27/PSD-LI33/LI37. 1.2. Copyright All text and image in this document are subject to the copyright of GS Instech Co., Ltd. This document may not be reproduced, distributed, or modified without the written permission of GS Instech Co., Ltd. 1.3.
Version Date 1.0 Title USER MANUAL NOV. 27, 2018 Prepared by Reviewed by KO. SUNGMOO 7 © 2018 GS Instech Co., Ltd. All rights reserved.
Version Date 1.0 Title USER MANUAL NOV. 27, 2018 Prepared by Reviewed by KO. SUNGMOO Figure 1. FCC/ UL Certification Statement [Class A] 8 © 2018 GS Instech Co., Ltd. All rights reserved.
Version Date 1.0 Title NOV. 27, 2018 Prepared by USER MANUAL Reviewed by Page 9/ 42 Approved by KO. SUNGMOO Figure 2. FCC/ UL Certification Statement [Class B] The user’s manual or instruction manual for an intentional or unintentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Version Date 1.0 Title NOV. 27, 2018 Prepared by USER MANUAL Reviewed by Page 10/ 42 Approved by KO. SUNGMOO 1.3.1 FCC Part 15.105 This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Version Date 1.0 Title NOV. 27, 2018 Prepared by USER MANUAL Reviewed by Page 11/ 42 Approved by KO. SUNGMOO 1.4. Antenna installation Antennas must be installed in accordance with FCC 90.635. The height of the antenna above average terrain (HAAT) must not exceed limit in the following table. Type SU DU Model name(s) HAAT (m) Antenna again PSS-DAS-LI33 444.65 3dBi PSS-DAS-LI37 281.43 3dBi PSD-DAS-LI27 212.17 15dBi 11 © 2018 GS Instech Co., Ltd. All rights reserved.
Version Date 1.0 Title NOV. 27, 2018 Prepared by USER MANUAL Reviewed by Page 12/ 42 Approved by KO. SUNGMOO Introduction 2. 2.1. System Overview PS-DAS is designed to improve coverage and capacity of Public Safety networks. Receiving signal via antenna, it provides coverage Building in RF shadow. Figure 3. PS-DAS Application Configurations 12 © 2018 GS Instech Co., Ltd. All rights reserved.
Version Date 1.0 Title NOV. 27, 2018 Prepared by USER MANUAL Reviewed by Page 13/ 42 Approved by KO. SUNGMOO 2.2. Main Features ● All-in One Donor Unit - Compose several units such as Optic Transceiver, NMS, PSU, BDA, Cavity Filter etc.
Version Date 1.0 Title Prepared by USER MANUAL 3. NOV. 27, 2018 Reviewed by KO. SUNGMOO System Design for PSD-LI27 (Donor Unit) 3.1. Exterior View Figure 4. PSD-LI27 Exterior View 14 © 2018 GS Instech Co., Ltd. All rights reserved.
Version Date 1.0 Title NOV. 27, 2018 Prepared by USER MANUAL Page Reviewed by KO. SUNGMOO 3.2. Interior View Figure 5. PSD-LI27 Interior View No Name Remark 1 DFU 700/800 Digital Filter Unit 2 RFU 700/800 RF Unit 3 PSU In : DC +48V / Out : DC +28V 4 Cavity Filter Duplexer for 700/800M 5 DOU1 Donor Optic Unit (2Port) 15 © 2018 GS Instech Co., Ltd. All rights reserved.
Version Date 1.0 Title NOV. 27, 2018 Prepared by USER MANUAL Reviewed by Page 16/ 42 Approved by KO.
Version Date 1.0 Title NOV. 27, 2018 Prepared by USER MANUAL Reviewed by Page 17/ 42 Approved by KO. SUNGMOO 3.3. External Interface Figure 6. PSD-LI27 External Interface No NAMES DESCRIPTION 1 DC IN DC Input Outlet MS3102A 14S-9P 2 LAN Communicate a data between DU and Server RJ-45 Waterproof 3 ANT Feeding Downlink Signal / Transmit Uplink Output 4.
Version Date 1.0 Title Prepared by USER MANUAL 4. NOV. 27, 2018 Reviewed by KO. SUNGMOO System Design for PSS-LI33 (Service Unit) 4.1. Exterior View Figure 7. PSS-LI33 Exterior View 18 © 2018 GS Instech Co., Ltd. All rights reserved.
Version Date 1.0 Title NOV. 27, 2018 Prepared by USER MANUAL Page 19/ 42 Reviewed by Approved by KO. SUNGMOO 4.2. Interior View Figure 8.
Version Date 1.0 Title NOV. 27, 2018 Prepared by USER MANUAL Reviewed by Page 20/ 42 Approved by KO. SUNGMOO 4.3. External Interface Figure 9.PSS-LI33 External Interface No NAMES DESCRIPTION 1 DC IN DC Input Outlet MS3102A 14S-9P 2 ANT Feeding Uplink Signal / Transmit Downlink Output 4.3-10 Din Connector 3 External Alarm External Alarm Panel connect MS3102A 22-14P 4 OPTIC 0 Insert the optic cable to Donor Unit Metal Cable Gland Table 4.
Version Date 1.0 Title Prepared by USER MANUAL 5. NOV. 27, 2018 Reviewed by KO. SUNGMOO System Design for PSS-LI37 (Service Unit) 5.1. Exterior View Figure 10. PSS-LI37 Exterior View 21 © 2018 GS Instech Co., Ltd. All rights reserved.
Version Date 1.0 Title NOV. 27, 2018 Prepared by USER MANUAL Page Reviewed by KO. SUNGMOO 5.2. Interior View Figure 11.
Version Date 1.0 Title NOV. 27, 2018 Prepared by USER MANUAL Reviewed by Page 23/ 42 Approved by KO. SUNGMOO 5.3. External Interface Figure 12. PSS-LI37 External Interface No NAMES DESCRIPTION 1 DC IN DC Input Outlet MS3102A 14S-9P 2 External Alarm External Alarm Panel connect MS3102A 22-14P 3 Vent-Core Maintain Humidity & Temp Inside IP66 4 ANT Feeding Uplink Signal / Transmit Downlink Output 4.
Version Date 1.0 Title 6. NOV. 27, 2018 Prepared by USER MANUAL Page 24/ 42 Reviewed by Approved by KO. SUNGMOO System Specification 6.1. RF Performance Parameter Frequency Range Input Range Output Power Range Gain Down Link Up Link Remark 758MHz~768MHz 788MHz~798MHz LTE 769MHz~775MHz 799MHz~805MHz P25 851MHz~861MHz 806MHz~816MHz P25 -62dBm ~ -17dBm/ Total -62dBm Per Band +33dBm with PSS-LI33 +27dBm(0.
Version Date 1.0 Title NOV. 27, 2018 Prepared by USER MANUAL Page 25/ 42 Reviewed by Approved by KO. SUNGMOO Frequency Information 6.2. 6.2.1. Frequency Information No DL UL NAMES DESCRIPTION SPECIFICATION 700 (PSBB) 758MHz ~ 768MHz LTE 700 (PSNB) 769MHz ~ 775MHz P25 800 (PSNB) 851MHz ~ 861MHz P25 700 (PSBB) 788MHz ~ 798MHz LTE 700 (PSNB) 799MHz ~ 805MHz P25 800 (PSNB) 806MHz ~ 816MHz P25 Table 8. PS-DAS Frequency Allocation 6.2.2. Block Diagram Figure 13.
Version Date 1.0 Title NOV. 27, 2018 Prepared by USER MANUAL Reviewed by Page 26/ 42 Approved by KO. SUNGMOO 6.2.3. Service Plan 1) The LTE network integrates Upper D band and FirstNet to have max. 10MHz Service BW. 2) The P25 Network has a Guard Band of 768-769MHz and 775-776MHz. Figure 14. 700MHz Band Allocation Figure 15. 800MHz Band Allocation 26 © 2018 GS Instech Co., Ltd. All rights reserved.
Version Date 1.0 Title NOV. 27, 2018 Prepared by USER MANUAL Page 27/ 42 Reviewed by Approved by KO. SUNGMOO 6.3. Configuration & Mechanical Specification Parameter Specification Remark Donor/ Service Antenna Filter DUPLEXER+BAND COMBINER One port In/Output Power Supply DC Input Voltage: 48VDC Operation Temperature -40°C~+60°C (5~95%RH) Storage Temperature -40°C~+80°C (5~95%RH) Connectors Antenna 4.3-10 Mini DIN Female Power MS-3106A 14S-9P Ext.
Version Date 1.0 Title NOV. 27, 2018 Prepared by USER MANUAL Page 28/ 42 Reviewed by Approved by KO. SUNGMOO 6.4. External Alarm Connect Alarm No. Alarm1 Alarm2 Alarm3 Alarm4 External Alarm Input. #1 External Alarm Input. #2 Alarm Name User Defined User Defined User Defined User Defined User Defined User Defined Pin No.
Version Date 1.0 Title Prepared by USER MANUAL 7. NOV. 27, 2018 Reviewed by Page 29/ 42 Approved by KO. SUNGMOO System Block Configuration 7.1. Block Diagram Figure 16. PSD-LI27 Block Diagram Configuration The repeater improves service in the Dual Band Public safety networks. User may select frequency band according to the site peculiarities. After receiving a weak signal from Donor antenna, the PSD-LI27 sends downlink signal to PSS-LI33/37 using DOU.
Version Date 1.0 Title USER MANUAL NOV. 27, 2018 Prepared by Reviewed by Page 30/ 42 Approved by KO. SUNGMOO PSS-LI33/37 is operating very similar to the PSD-LI27 After receiving an Uplink Signal from service antenna, the PS-DASD-LI33/37 sends Uplink signal to PSD-LI27 using SOU (Service Optic Unit). SOU supports the translation of RF signal to Optic signal for connecting PSD-LI27 through the fiber optic cable.
Version Date 1.0 Title 8. NOV. 27, 2018 Prepared by USER MANUAL Page 31/ 42 Reviewed by Approved by KO. SUNGMOO GUI Overview • Provide all functions that can be performed at Service Unit will be available thru the Donor Unit. • Support the GUI pages that will be addressable via UDP Interface. 8.1. Configuration the Laptop to Connect to the Repeater • Connect an Ethernet crossover cable from the LAN port of the repeater’s bottom side to your laptop 1. Go to Local Connection 2.
Version Date 1.0 Title NOV. 27, 2018 Prepared by USER MANUAL Reviewed by Page 32/ 42 Approved by KO. SUNGMOO 8.2. Login-In Screen • GUI Screen for Log-In • Enter the IP Address ① "192.168.2.1" and Port into GUI Main Screen. And then ② Connect. • If the window at the top of the screen ③blinks green, you can verify that the connection has completed successfully. • The laptop connected to the System, you can check ⑤ Topology tree of the PS-DAS by pressing the System button on the screen.
Version Date 1.0 Title USER MANUAL NOV. 27, 2018 Prepared by Reviewed by KO. SUNGMOO 8.3. RF Status • GUI Screen for display Repeater’s RF Status 33 © 2018 GS Instech Co., Ltd. All rights reserved.
Version Date 1.0 Title USER MANUAL NOV. 27, 2018 Prepared by Reviewed by Page 34/ 42 Approved by KO. SUNGMOO 8.4. SU Configuration • GUI Screen in order to change the RF values • User may change the various RF values of the repeater on this page • Changes will not take effect until you click "Apply" button • This menu is where the installer will choose references for specific implementation • ① in the GUI screen shows SOU behavior, PD / LD Power Level detection, and SOU related alarms.
Version Date 1.0 Title NOV. 27, 2018 Prepared by USER MANUAL Reviewed by KO. SUNGMOO 8.5. Band Selection • Repeater support the capacity of P25 and LTE Technologies • For P25, 32 non-contiguous bands can be used • Support the LTE 5MHz, 10MHz • User can set the desired channel using the GUI 35 © 2018 GS Instech Co., Ltd. All rights reserved.
Version Date 1.0 Title Prepared by USER MANUAL 9. NOV. 27, 2018 Reviewed by Page 36/ 42 Approved by KO.
Version Date 1.0 Title Prepared by USER MANUAL 9.1. NOV. 27, 2018 Reviewed by Page 37/ 42 Approved by KO. SUNGMOO Warnings and Hazards 9.1.1. Electric Shock • Opening the Repeater could result in electrical shock and may cause severe injury • Operating the Repeater with antennas in very close proximity facing each other could lead to severe damage to the repeater 9.1.2.
Version Date 1.0 Title NOV. 27, 2018 Prepared by USER MANUAL Reviewed by Page 38/ 42 Approved by KO. SUNGMOO 9.2. Service Man Installation Guide 9.2.1. PSS-LI37 Fixing the Wall Mount Type The procedure for fixing the pole type system is as follows. 1) To mount the system on the wall, first fix the bracket on the wanted position. 2) Hang the system to the hooking position at the top of the mounting bracket 3) Push the system to the hooking position at the bottom of the mounting bracket. Figure 18.
Version Date 1.0 Title NOV. 27, 2018 Prepared by USER MANUAL Reviewed by Page 39/ 42 Approved by KO. SUNGMOO 4) Align the system with the fixing holes of the mounting bracket and fix them firmly 9.2.2. PSD-LI27 / PSS-LI33 Fixing the Wall Mount Type 39 © 2018 GS Instech Co., Ltd. All rights reserved.
Version Date 1.0 Title NOV. 27, 2018 Prepared by USER MANUAL Reviewed by Page 40/ 42 Approved by KO. SUNGMOO Figure 19.The way to fix firmly the System for Wall Mounting Cautions System leveling Before fixing the system, Check the horizontal and vertical level using a spirit level 40 © 2018 GS Instech Co., Ltd. All rights reserved.
Version Date 1.0 Title NOV. 27, 2018 Prepared by USER MANUAL Reviewed by Page 41/ 42 Approved by KO. SUNGMOO 9.3. Cable Connection 9.3.1. DC Power cable connection • Repeater supports a free DC Input voltage 48V • Provided Power cable is single type, so it can be used flexibly • The pin description of DC Port is below.
Version Date 1.0 Title NOV. 27, 2018 Prepared by USER MANUAL Page Reviewed by KO. SUNGMOO 9.3.4. Grounding cable Connection • Frame(Earth) Wire size is AWG #6. The way to install the grounding cable is below • The specification of ground terminal lug is like below (Refer to JOCT 0202-RL05) Frame Ground 42 © 2018 GS Instech Co., Ltd. All rights reserved.