GT915/916/917/918 INSTALLATION AND USER MANUAL Getronic S.r.l. Via Calcinate No.12 21026 Gavirate (VA) Italy Tel. +39 0332 756011 Fax + 39 0332 731162 www.gtalarm.
SUMMARY 1.0 - GENERAL DESCRIPTION 2.0 - INSTALLATION AND CONNECTIONS 3.0 - CONNECTION DIAGRAM 4.0 - INDICATOR COMMAND DIAGRAM 5.0 - GT931 ULTRASONIC KIT CONNECTION(only for GT915) 6.0 - CENTRAL DOOR LOCKING DIAGRAMS 7.0 - SET FUNCTIONS 8.0 - USER MANUAL 9.0 - MAINTENANCE AND WARNINGS 10.0 - COMPLIANCE DECLARATION 11.0 - TECHNICAL DATA 12.0 - WARRANTY CONDITIONS Page 2 Page 3 Page 4 Page 5 Page 5 Page 6 Page 8 Page 11 Page 14 Page 15 Page 15 Page 16 1.
2.0 - INSTALLATION AND CONNECTIONS WARNINGS: - Complete a pre-installation check and disconnect the negative terminal of the vehicle’s battery. . - Before fixing the device, insert the installation loom connectors into the alarm and screw the connector cover on. - Place the alarm system in the engine compartment, away from direct sources of water spray and high tension wiring. - Solder and isolate all connections.
- The WHITE and GREY wires (Max. capacity 7 mA) are used for the engine immobilisation either on the diesel or petrol vehicles. Cut the ignition switched wire which supplies the fuel pump or electrovalve (diesel vehicles). Connect the two wires one to the GREY wire and the other to the WHITE one. - Place the LED/RECEPTACLE on the dashboard (so that it is easily visible and accessible) and join together the connector with the connector on the alarm loom. 3.
4.0 - INDICATOR COMMAND DIAGRAM - The ORANGE wire connection as mentioned below has to be carried out only if the function No.5 INDICATOR COMMAND IS ENABLED. - When the ORANGE/BLACK wire connection is made you must use a 1N4007 diode.
.0 - CENTRAL DOOR LOCKING DIAGRAMS DIAGRAM No.3 (Unlocking = 1" - Locking = 1") GT ALARM YELLOW/GREY RED/GREY +30 COMMAND BUTTON YELLOW/BROWN M 10 AMP FUSE - YELLOW/BLUE CENTRAL DOOR LOCKING ACTUATORS +30 + RED/BROWN RED/BLUE 10 AMP FUSE POSITIVE COMMAND WHEN UNLOCKING CUT POSITIVE COMMAND WHEN LOCKING M CUT DIAGRAM No.
DIAGRAM No.5 (Unlocking = 1" - Locking = 1") GT 71 ACTUATOR GT ALARM YELLOW/GREY +30 RED/GREY 5 AMP FUSE LIGHT BLUE RED/BLUE YELLOW/BROWN RED YELLOW/BLUE RED/BROWN DIAGRAM No.
7.0 - SET FUNCTIONS The system is equipped with a “SET FUNCTIONS” which allows to program and customize the alarm following to the user needs. To access to the SET FUNCTIONS: 1 - The alarm must be disarmed. 2 - Switch the vehicle ignition key on, place the GT888 handsets contacts to the receptacle and check that 5 quick beeps are emitted and the RED LED will switch on constant. The alarm is in SET FUNCTIONS mode. Switch the ignition key off. 3 - After 5 seconds starting from the function No.
SET FUNCTIONS TABLE No.
- Function No. 2: RAPID TEST. With this function it is possible to check the correct installation carrying out a test of all the alarm connections. Additional modules entry test: triggering the sensor (ultrasonic microwaves, inclination etc.) the system generates 1 beep and No.1 GREEN flash of the del LED on the receptacle. DOORS pin switch test: opening one or more doors the system generates 4 beeps and 4 GREEN flashes of the LED on the receptacle.
8.0 - USER MANUAL - HANDSET DESCRIPTION. GT888 GT884N (Optional) PANIC LED GT888: 3 button handset with electronic key incorporated. LED GT884N: 1 multifunction button (Optional). - “ON/OFF”:button: to arm and disarm the alarm. - With automatic transmission selectable if required. ON-OFF DOUBLE LOCKING ON/OFF - MANUAL ARMING / DISARMING. ARMING by HANDSET: Press the “ON/OFF” handset button, the arming is confirmed by an indicator flash,and by a Beep and the LED will start to flash.
- DOUBLE LOCKING. In the first 5 seconds after the system is armed and the doors lock press the lock button on the handset a second time and the double locking if connected will be set this is confirmed by a second tone and flash of the indicators. - COMFORT CLOSING. If this function is ENABLED, on the vehicles equipped with this function, the window closing occurs automatically.
- IN CASE OF ALALRM. - Press the “ON/OFF” button to disarm the system. - Press the “PANIC” button to stop the alarm cycle without disarming (only with GT888). - ALARMS CHECK CONTROL AND ANOMALIES. LAST ALARM CAUSE: If during the armed state an alarm has been detected (4 indicators flashes and 4 beeps to the disarming) or there is anomaly it is possible to check the cause.
9.0 - MAINTENANCE AND WARNINGS MOTOR VEHICLEWASHING. It is necessary to pay particular attention to any source of water spray. It is advisable, during this operation to protect it with a covering (i.e. cellophane). - FUNCTIONS CHECK. To have an always efficient system it is advisable to carry a periodic check of all the functions. - HANDSET. Do not expose the handset to excessive heat sources, water and shocks. For the battery replacement refer the picture below.
10.0 - COMPLIANCE DECLARATION Getronic S.r.l. Via Calcinate, 12 Gavirate, Italy hereby declares that GT915/916/917/918 are in compliance with the following European Directive: R&TTE 1999/5/CE (including the directives: 95/54CE) All Getronic products are compatible with the vehicle’s original electronic systems. The GT888/884N handsets are in compliance with sthe following European Directives: EMCC DR.
Installation Certificate We certify that the alarm system installation has been carried out following these fitting and that the technical data has been handed over. Warranty coupon Alarm model ALARM MODEL: INSTALLATION DATE: INSTALLED ACCESSORIES: POSSIBLE INSTALLED ACCESSORIES: STAMP AND INSTALLER SIGNATURE: INSTALLATION DATE: STAMP AND INSTALLER SIGNATURE CUT AND KEEP MAKE AND CAR MODEL: CUT AND KEEP 12.