User's Manual

Estate Intercom/Keypad Features
Keypad
The keypad illuminates and beeps at the press of any key. At night, the keypad will illuminate when the proximity sensors
detect motion near the keypad face.
When a valid code is entered, the STATUS light will blink rapidly, the keypad will beep three times, and the GRANTED
light turns green.
The keypad remains active for 40 seconds after entering a valid code: pressing any key on the keypad while the gate is
in motion will stop the gate; pressing any key while the gate is stopped will cause the gate to reverse direction. After 40
seconds, the keypad will
beep 3 three times and go into “idle” mode, and the GRANTED light will turn off.
If more than 20 key presses are entered without matching an Entry Code, the STATUS light will flash rapidly, an error tone
will sound for 1 second, and the keypad will go into “lock-down” mode for 40 seconds.
If more than 10 seconds elapse between key presses, the keypad will beep 3 three times and go into “idle” mode.
Master and Entry Codes
Up to 100 Entry Codes may be programmed into the keypad.
Temporary Entry Codes can be programmed to expire within one to seven (1–7) days.
Entry Codes remain stored in memory even when the keypad batteries go dead.
All Entry Codes are deleted by pressing the RESET button on the keypad; Master Code defaults to “1234.”
Base Unit
The base unit is powered by a rechargeable battery (included); the charge is maintained by the transformer.
The base unit can be disconnected from the transformer allowing it to be moved anywhere within range.
Up to three additional base units can be added to the system.
NOTE: The keypad, not the base station, initiates the call and operates the gate. The base station is for answering
calls and granting “permission” for the gate to be opened.
INTERCOM/KEYPAD SPECIFICATIONS
Frequency 318 MHz from keypad to gate opener
915 MHz from keypad to base station
Memory – Keypad Stores up to 100 four-digit entry codes
Power Consumption – Keypad 60 mA when relay is closed
Power Supply – Keypad Four C batteries (plus 8-24V DC/AC for hard-wired installations)
Power Supply – Base Unit 9 Vdc 300 mA transformer; 3.6V Ni-MH 800 mA rechargeable battery
pack
Range from Keypad to Base Unit 500’ wireless
Range from Reypad to Gate Opener 50’ wireless 100’ wired using 16 AWG wire
Relay Output – Keypad Momentary, normally open dry contact closes for 2 seconds upon
activation
Relay Output Rating – Keypad 12 or 24 Vdc 100 mA
Wiring – Keypad Power & Relay Output 16 AWG stranded low voltage direct burial wire