User's Manual
 GTO 4000XLS Instruction Manual © 01.10.12 19
Connecting Accessories
Input Connections
 • Allcontrolinputsaredry-contact,normallyopen,inputs.DONOTapplyexternalvoltagesourcesto
these inputs.
 • AllinputsareconnectedwithrespecttoCOMMONterminal.
 • ThestatusLEDwillblinkoncewhenitscorrespondinginputisactivated.
1 COM: Circuit common (reference for 
all logic input)
 •Two(2)terminalstoprovideextra
common connection point.
2 CYCLE/CLOSE:  (Typically for use 
with push button or hard-wired 
keypad)
 • Eachactivationatthisinputwill
cycle the operation as follows:
 OPEN–STOP–CLOSE–STOP–OPEN 
3 SAFETY: (Typically for use with 
photo beam device, loop detector 
or other non-contact sensors)
 • Activationofthisinputwhilethe
gate is closing will cause the gate 
to stop and return to the opened 
position.
 • Activationofthisinputwhilethe
gate is opening has no eect (gate 
will continue to open).
 • Activationofthisinputwhile
gate is idle will prevent gate from 
closing.
4 EXIT/OPEN: (Typically for use with 
exit loop or wand)
 • Activationofthisinputwillopen
thegateifit’snotalreadyattheopenposition
 • Activationofthisinputwhileatopenlimitwillrestarttheautoclosetime(ifenabled).
 • Activationofthisinputwhilegateatthefullyopenpositionwillpreventgatefromclosing.
5  SHADOW LOOP:  (Typically for use with loop detector)
 • Thisinputisonlymonitoredwhenthegateisatthefullyopenposition.Atanyotherposition,
activation of this input has no eect on gate operation.
 • Activationofthisinputwhilegateatthefullyopenpositionwillpreventgatefromclosing.
6  CLOSE EDGE:  (Typically for use with safety edge device)
 • Activationofthisinputwhilethegateisclosingwillcausethegatetostopandreversedirectionfor
approximately 2 seconds.
 • Activationofthisinputwhilethegateisopeninghasnoeect(gatewillcontinuetoopen).
 • Activationofthisinputwhilegateisidlewillpreventgatefromclosing.
7  OPEN EDGE: (Typically for use with safety edge device)
 • Activationofthisinputwhilethegateisopeningwillcausethegatetostopandreversedirectionfor
approximately 2 seconds.
 • Activationofthisinputwhilethegateisclosinghasnoeect(gatewillcontinuetoclose).
 • Activationofthisinputwhilegateisidlewillpreventgatefromopening.
GRNCOMCOM
CYCLE
CLOSE
SAFETY
SHADOW
LOOP
CLOSE
EDGE
OPEN
EDGE
EXIT
OPEN
BLK
RECEIVER
RED
RECEIVER
ALM
CONTROL INPUTS
1
2
3
4
7
5
6