User Manual
UHF Integrated RFID Reader Manual
Guangdong Sygole Intelligent Technology Co.,Ltd
9
Installing the reader in the metal frame - avoiding the conductor loop
Fig 3.4.3 Round metal frame installation
3.5Electromagnetic compatibility
3.5.1 Electromagnetic compatibility guidelines
Electromagnetic compatibility refers to the ability of an electronic device to
function properly in an electromagnetic environment.Electromagnetic
interference is an electromagnetic phenomenon that is detrimental to the
performance of electronic equipment.Electromagnetic interference not only
affects the normal operation of electronic equipment, but even causes damage to
certain components in electronic equipment. With the increase in automation, the
arrangement of electrical and electronic equipment becomes more complicated,
and the risk of interaction between devices is increased.Electromagnetic
interference mainly consists of three parts: interference source, coupling path
and interference receiver. When applying the implementation plan in the field, it
is necessary to identify the most frequent sources of interference and the possible
coupling paths that exist, so as to take corresponding measures to reduce the risk
of electromagnetic interference and ensure the normal operation of the
equipment.
In order to ensure electromagnetic compatibility enough, the following rules
must be observed:
1、The device is shielded by the outer casing. The reader-related equipment
is installed in the cabinet and grounded through the rack to shield the external
If the reader is in a closed metal frame, the metal frame will reflect
and disturb the electromagnetic wave signal. At this time, the antenna
field and the transmitting field over-lap each other, and the reader
cannot receive the valid signal normally, resulting in abnormal
reading. The closer the metal frame is to the reader, the greater the
interference, and the installation should be avoided in practical
applications.