magnetic field.
2The equipment is well grounded. Good grounding can ensure the clean
power supply of the equipment, and on the other hand,it can prevent the
excessive impact voltage from being damaged when the equipment fails, and
damage the reader.
3Cable shielding. For sites with complex electromagnetic environments,
shielded communication cables must be used to avoid interference signals being
coupled to the cables.
4Signal and line filtering. Install the filter in the power inlet or cabinet
inlet direction to avoid interference from the power source into the device.
3.5.2 Power supply and wiring requirements
In an industrial environment, a major source of interference in equipment circuits is
caused by unreasonable ground lines.Therefore, proper grounding is an important
method to suppress noise and prevent interference, and is the key to ensure the normal
operation and read/write success rate of the reader.
Under normal circumstances, the reader device power supply voltage of 24V, which is
weak current. When wiring, connect the power supply line of the reader and the 485
power supply line from the weak current slot, and the cable slot must be connected to
the standard earth“0”Level.
3.5.3 Common electromagnetic interference causes and solutions
The following provides a reference to some common electromagnetic
interference solutions
The switching power supply interferes from the current conduction to the
device. It can be solved by replacing the independent power supply or adding
a filter at the power supply.
Cable couple Electromagnetic interference in the space. Insufficient cable
shielding or the reader is not well grounded, which can be solved by
improving the shielding performance of the cable and making the reader well
grounded.
Antenna interference between readers. It can be solved by increasing the
safety spacing of adjacent readers and reducing the transmit power of the
reader.
Control cabinet or chassis interference. The electrical planning of the control
cabinet or the casing is unreasonable, the grounding is missing or bad, and
the0potential imbalance causes interference, which can be solved by
rationally designing the control cabinet or the casing.
Note: If the grounding of the slot and shield is not guaranteed to
be the standard "0" potential, you need to provide independent
power for the RFID or add a filter to the power supply.