6.1 Field bus communication mode
In some cases, the field bus communication mode should be adopted to meet such
application requirements for large amount of RFID reader heads and high data
timeliness.Sygole I81/I82/I83 series products can support the field bus through gateway
controller, and support such protocols as ProfiNet, EtherCAT, Ethernet/IP, DeviceNet,
CCLINK and MODBUS TCP. Specifically, readers are connected to the gateways
which are mutually connected in series. In this way, all readers can be connected to the
same network. The networking mode is as follows:
6.2 POE communication mode
When RFID system is directly connected to MES system or the field cannot be used
due to economic problem, it is also a good choice to connect all RFID equipment
together through TCP/IP. The networking mode is as follows: