User's Manual

Tie the cuff
1.
2.
3.
2~3cm
4.
Tie the cuff on your upper arm, then
position the tube off-center toward
the inner side of arm in line with the
little finger. Or position the artery
mark over the main artery (on the
inside of your arm). Note: Locate the
main artery by pressing with 2 fingers
approximately 2 cm above the bend
of your elbow on the inside of your
left arm. Identify where the pulse can
be felt the strongest. This is your
main artery.
The cuff should be snug but not too
tight. You should be able to insert
one finger between the cuff and your
arm.
Sit comfortably with your tested arm
resting on a flat surface.
Patients with Hypertension:
The middle of the cuff should be
at the level of the right atrium of the
heart; Before starting measurement,
please sit comfortably with legs
uncrossed, feet flat on the floor, back
and arm supported.
Rest for 5 minutes before
measuring.
Wait at least 3 minutes between
measurements. This allows your
blood circulation to recover.
For a meaningful comparison, try to
measure under similar conditions.
For example, take daily
measurements at approximately the
same time, position of upper arm, or
as directed by a physician.
4.The monitor will shut off after Pair-up process is complete.
Bluetooth Module No.: AW51822
RF Frequency Range: 2402 MHz to 2480 MHz
Output Power Range: 4 dBm
Supply Voltage: 1.8V-3.6 V
Transmitting Distance: 10 meters
CAUTION
1.
2.
List of compatible devices:
For iOS devices:
The operating system must be iOS 8 or more, such as iPhone
4S, iPhone 5/5C/5S, iPhone 6/6 Plus and so on.
For Android devices:
The operating system must be 4.3 or more.
Interference may occur in the vicinity of equipment marked with the following
symbol . And TMB-1597-BN may interfering vicinity electrical equipment.
Sensitive people, including pregnant women pre-eclamptic and those who
implanted medical electronic instruments, should avoid using the unit
whenever possible.
Keep the monitor at least 20 centimeters away from the human body
(especially the head) when the data transmission is proceeding after
measurement.
To enable the data transmission function, this product should be paired to
Bluetooth end at 2.4 GHz.
How to mitigate possible interference?
The range between the device and BT end should be reasonably close, from
1 meter to 10 meters. Please ensure no obstacles between the device and
BT end so as to obtain quality connection and to lower the RF output range.
To avoid interference, other electronic devices (particularly those with
wireless transmission / Transmitter) should be kept at least 1 meter away
from the monitor.
15
14
MEASUREMENTBEFORE YOU START