version:1.0 User Manual Blood Pressure Monitor TMB-1776-B Arm Type FCC ID:OU9TMB1776B2 Guangdong Transtek Medical Electronics Co., Ltd. Zone A, No.105 ,Dongli Road, Torch Development District, 528437 Zhongshan,Guangdong,China Thank you very much for selecting TRANSTEK Blood Pressure Monitor TMB-1776-B. Please read the user manual carefully and thoroughtly so as to ensure the safe usage of this product, and keep the manual well for further reference in case you have problems.
CATALOGUE Table of Contents INTRODUCTION..................................................................................................................2 General Description Indications for Use Contraindications Measurement Principle Safety Information LCD Display Signal Monitor Components List BEFORE YOU START..........................................................................................................
INTRODUCTION General Description Thank you for selecting TRANSTEK arm type blood pressure monitor (TMB-1776-B). The monitor features blood pressure measurement, pulse rate measurement and the result storage. The design provides you with two years of reliable service. Readings taken by the TMB-1776-B are equivalent to those obtained by a trained observer using the cuff and stethoscope auscultation method.
INTRODUCTION CAUTION * This device is intended for indoor, home use. * This device is not intended for public use. * This device is portable, but it is not intended for use during patient transport. * This device is not suitable for continuous monitoring during medical emergencies or operations. * This device is intended for no-invasive measuring and monitoring of arterial blood pressure.
INTRODUCTION INTRODUCTION LCD display signal Monitor Components Component list of pressure measuring system 1 Cuff 2 Air pipe 3 PCBA 4 Pump 5 Valve CUFF AIR HOSE AIR CONNECTOR PLUG USER BUTTON MEMORY BUTTON SYMBOL / 6 DESCRIPTION START/STOP BUTTON EXPLANATION Systolic pressure High blood pressure Diastolic pressure Low blood pressure Pulse display Pulse in beats per minute DC POWER SOCKET LCD DISPLAY mmHg Measurement Unit of the blood pressure (1mmHg=0.
BEFORE YOU START BEFORE YOU START Setting Date and Time. The Choice of Power Supply It is important to set the clock before using your blood pressure monitor, so that a time stamp can be assigned to each record that is stored in the memory. (The setting range of the year :2019—2059; Time format:12H) 1.Battery powered mode: 6VDC 4×AA batteries 2 . AC adaptor powered mode: 6V 1A (Please only use the recommended AC adaptor model). Please unplug the adaptor to depart from the using utility power.
BEFORE YOU START 4.Repeat step 2 and 3 to set the [MONTH] and [DAY]. BEFORE YOU START Select the User ID 1. Before you start the measurement, please select the desired user ID first. When the blood pressure monitor is off, press USER button the user ID will blink. Then press USER button again to change the user ID between user A and user B. 5 .Repeat step 2 and 3 to set the [HOUR] and [MINUTE]. 2.
BEFORE YOU START MEASUREMENT Pair up with Your Device (1)Turn on Bluetooth and the app. Make sure both are ON when pair-up is proceeding. (2)When the monitor is OFF, press and hold the MEM button to start pair-up. The below picture will be shown on the LCD alternatively,indicating pair-up is proceeding. Tie the cuff 1. Remove all jewelry, such as watches and bracelets from your left arm. Note: If your doctor has diagnosed you with poor circulation in your left arm, use your right arm. 2.
MEASUREMENT MEASUREMENT Start the Measurement 1. When the monitor is off, press START/STOP button to turn on the monitor, the user ID will blink ,confirm the User ID, then press “START/STOP” button again and it will finish the whole measurement. (Take user A for example.) LCD display If the data transmission fails, the Bluetooth symbol blinks all the time until it turns off. Adjust the zero. If the data transmission succeeds, the Bluetooth symbol will not blink and then turn off.
DATA MANAGEMENT DATA MANAGEMENT Recall the Records 1. When the monitor is off, please press MEM button to confirm the User, then press START/STOP button to show the latest record . Press the MEM button again to show the average value of the latest three records.If the records are less than 3 groups, it will display the latest record instead. Delete the Records If you did not get the correct measurement, you can delete the result for the selected user by following steps below . A: Delete one record 1.
DATA MANAGEMENT B: Delete all records 1.Hold pressing both USER button and MEM botton for 3 second when the monitor is in the memory recall mode,the flash display “dEL yES + ” will show to delete all result. 2. Press USER button or MEM button the flash displays “dEL no” or “dEL yES” . 3. Press START/STOP button to confirm deleting when it shows “dELyES”,then the monitor with turn off when it shows “User + donE”.
INFORMATION FOR USER ABOUT BLOOD PRESSURE What are systolic pressure and diastolic pressure? Maintenance In order to get the best performance, please follow the instructions below. When ventricles contract and pump blood out of the heart, the blood pressure reaches its maximum value in the cycle, which is called systolic pressure. When the ventricles relax, the blood pressure reaches its minimum value in the cycle, which is called diastolic pressure.
ABOUT BLOOD PRESSURE TROUBLE SHOOTING Why does my blood pressure fluctuate throughout the day? 1. Individual blood pressure varies multiple times everyday. It is also affected by the way you tie your cuff and your measurement position, so please take the measurement under the same conditions. 2.If the person takes medicine, the pressure will vary more. 3.Wait at least 3 minutes for another measurement.
SPECIFICATIONS AUTHORIZED COMPONENTS Authorized Components Power supply Display mode Measurement mode Measurement range Battery powered mode: 6VDC 4×AA batteries AC adaptor powered mode: 6V 1A (Please only use the recommended AC adaptor model). Digital LCD display V.A.80mm×58.5mm Oscillographic testing mode Rated cuff pressure: 0mmHg~299mmHg(0kPa ~ 39.9kPa) Measurement pressure: SYS: 60mmHg~230mmHg (8.0kPa~30.7kPa) DIA: 40mmHg~130mmHg (5.3kPa~17.
EMC GUIDANCE FCC STATEMENT FCC Statement FCC ID:OU9TMB1776B2 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
EMC GUIDANCE EMC GUIDANCE Table 2 Table 3 Guidance and manufacturer’s declaration – electromagnetic Immunity Guidance and manufacturer’s declaration - electromagnetic Immunity Immunity Test IEC 60601-1-2 Test level Electrostatic discharge (ESD) IEC 61000-4-2 ±8 kV contact ±2 kV, ±4 kV, ±8 kV, ±15 kV air ±8 kV contact ±2 kV, ±4 kV, ±8 kV, ±15 kV air Electrical fast transient/burst IEC 61000-4-4 ±2 kV for power supply lines ±1 kV signal input/output 100 kHz repetition frequency ±2 kV for power sup