User's Manual

User Manual
Andea Electronics http://www.gzandea.com 34/44
6 Test
6.1 Alarm Performance Test
1. Set the [Detection method - Way to check if book in Library] to "EAS", select
the corresponding detection type according to the type of tag, and set [Trigger
method] to "Alarm when detection":
During the detection, the EAS function of the book tag needs to be activated
to indicate it is an illegal tag. In this way, when the book passes the gate aisle,
the gate alarms.
Figure 33 Alarm Condition Setting Using EAS
2. Set the [Detection method - Way to check if book in Library] to "AFI", set the
matching AFI value in the AFI configuration parameters (for example: AFI
value is set to 07) and [Trigger alarm condition] is set to "Alarm when books
are detected":
When testing, when the tag with AFI value set to 07 passes through the gates,
the gate will alarm. Others will not alarm.
Note: When the gate detection AFI value is set to 00, all tags will alarm
and 00 means no tags will be filtered.