User's Manual

User manual
Guangzhou Andea Electronics Technology Co., Ltd. 19/39
http://www.gzandea.com
Figure 26 Configuration interface for Communication interface
Bus address: this parameter is mainly used on the RS485 bus. When multiple
readers are connected to a bus, different bus addresses need to be configured for
each device, with a value range of 1-255.
RS232/RS485it needs to be powered on again to take effect after setting. (Note:
this parameter is shared with RS485 interface)
Baud rate: serial communication rate, the default setting is 38400;
Parity: None, Odd, Even, the default setting is even.
USB:
Compound type: It needs to be powered on again to take effect.
A. HID Custom + Keyboard: HID custom interface + keyboard emulation output;
B. HID Custom + VCP: HID custom interface + virtual serial port
Note:
Keyboard emulation output: it is available in auto read mode;
Virtual serial port: need to install the driver.
Ethernet:
Enable Ethernet: check to enable.
Enable DHCP: check to enable.
Static IP: set IP, Mask and Gateway.
6.1.3. GPIO