User's Manual
User manual
Guangzhou Andea Electronics Technology Co., Ltd. 27/39
http://www.gzandea.com
B. Hex string output;
➢ Others data format:
A. Raw bytes output;
B. Hex string output;
⚫ Trigger:
Figure 34 Configuration interface for trigger
① Trigger way:
Periodic trigger, trigger reading data every N milliseconds;
② Periodic trigger parameters:
Internal(ms): trigger with an interval of N milliseconds;
Inventory count(0 means once): how many times to Inventory after triggering.
⚫ Filter:
Figure 35 Configuration interface for filter
UID effective time(100ms): It only outputs once when reading the same tag
within the valid time.
⚫ Serial output parameters: