Auto close RF power:
Enable:
If it is enabled, after the RF is turned on, it will be turned off when Idle time
exceeds the set time.
RF idle time(100ms): timeout.
Note: after the" Auto close RF power" function is enabled, the operation of
password authentication for the tag may cause failure.
6.2. Testing
6.2.1. Multi-tags Inventory Testing
After entering the main interface of R-Tool test software, select "ISO Multi-Tag
Test" ,carry out the procedure as shown in the following figure , and for tags
inventory test:
Number of last Tag counts
Tags list
Figure 38 Multi-Tag inventory test steps
Note:
Step 1: Select the menu "ISO Multi-Tag Test" in the main interface of the software;
Step 2: Select the "Inventory " in the drop-down list above the "Start" button;
Step 3: Click the "Start" button to carry out the inventory testing.