After inclusion, turn off the device and then turn it on. Now the device is ready to be operated by
controller/ gateway in Z-Wave network.
Association Group
Thermostat supports 1 association group. A gateway is suggested to associate with this
group. Then if any changes happen, such as: temperature, working mode, fan state etc., the
thermostat will report to this associated device (gateway). When the detected temperature change
0.5, device will send unsolicited report to the gateway.
Command Class supported by the device:
COMMAND_CLASS_BASIC;
COMMAND_CLASS_THERMOSTAT_SETPOINT;
COMMAND_CLASS_THERMOSTAT_MODE;
COMMAND_CLASS_THERMOSTAT_FAN_MODE;
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE;
COMMAND_CLASS_SENSOR_MULTILEVEL;
COMMAND_CLASS_ASSOCIATION;
COMMAND_CLASS_VERSION;
COMMAND_CLASS_MANUFACTURER_SPECIFIC
Z-Wave Parameters Setting:
Add
Function Byte
Options Default
Remark
1
Upload temperature
format automatically
1
0x00Celsius
0x01Fahrenheit 0x02Follow
the main display
0x02
2
Upload temperature
automatically
1
0x00 OFF
0x01 Upload the difference
value only
0x02 Timing upload mode only
0x03 Upload the
difference+timing upload mode
0x03
3
Upload temperature
difference
2
Base on 0.1unit, 0x0005 by
default, 5*0.1=0.5,
0x0003~0x03E8
0x0005
0.5