User's Manual
User Manual
4
8
Operation report
from Switch1 to
Association Group2
1
0x00 report ON/OFF state of S1 to AG2
0x01 only report ON state of S1 to AG2
0x02 only report OFF state of S1 to AG2
0xFF no report to AG 2
0x00
9
Switch 2 function
1
0x01 enable Scene Activation & send Basic
ON/OFF to associated devices
0x02 Scene Activation only
0x03 send Basic ON/OFF only
0xFF disable S2 Function
0x01
10
Operation report
from Switch2 to
Association Group3
1
0x00 send Basic ON or Basic OFF to AG3
when turn on/off S2
0x01 only send Basic ON when turn on S2
0x02 only send Basic OFF when turn off S2
0xFF no report to AG 3
0x01
11
Scene ID sent to
AG1 when one click
of S2
1
0 Scene Activation disabled
1~255 send Activation CC to AG1 with
specified Scene ID
0x00
12
Scene ID sent to
AG1 when double
click of S2
1
0 Scene Activation disabled
1~255 send Activation CC to AG1 with
specified Scene ID
0x00
For
momentary
button only
13
Scene ID sent to
AG1 when hold S2
1
0 Scene Activation disabled
1~255 send Activation CC to AG1 with
specified Scene ID
0x00
For
momentary
button only
255
Factory setting
1
0x55 restore factory setting (write only)
Restoring Factory Settings
The default configuration can be restored by:
Sending commands through controller or gateway (the command classes which support this
function is Configuration Command Class). The parameter are as follows:
Parameter Number
0xFF
Size
1 BYTE
Default value
N/A
Configuration value
0x55
Set 0xFF as 0x55 will restore Factory Settings.
Pressing and Holding the momentary button on device for 15s.
Note:If the Factory Settings is restored successfully, INDICATION LED will blink 6 times.