Specifications

SKI.W7603.1
9
QR-ZZPJ-017A
版权 CVTE 所有,本文档内容属商业机密。未经允许,任何组织或个人不得以任何形式复制和传播。
10-6
High
temperature
load life test
Thermostat cabinet
temperature:
55±5
Applied voltage:
110% rated voltage Working
duration: 200 hour (Supply
Voltage Cycle 23h power on,
1h power off)
60
After test, leave samples in standard
condition for 1 hour and test, Power, EVM
and Frequency error shall be satisfied
with the test specification.
10-7
High
temperature
load test
Temperature: 55±5
Samples work for 16 hours
3
After test, the Appearance, Power, EVM
and Frequency error shall be Satisfied
with the test specification.
10-8
Low
temperature
storage test
Leave the samples in
-25±3@24 hours
3
Leave samples in standard test condition
for 2 hours then test, the Appearance,
Power, EVM and Frequency error shall be
satisfied with the test specification.
10-9
Low
temperature
load test
Leave samples in -15±3@ 2
hours, samples’ function shall
be normal, the let samples
work for 1 hour
3
After test, leave the samples in standard
condition and tested the Appearance,
Power, EVM and Frequency error shall be
satisfied with the test specification.
After test, leave the samples in standard
10-10
Temperature
circle test
One cycle duration
-10±3@3H 40±3
@3H
3
condition and tested Power EVM and
Frequency error shall be qualified and all
the characters shall be satisfied with the
Total cycle: 10x
test specification.
10-11
Continuous
TP test
Twice cycle duration
-10±3@4H
+60±3@4H,
+25@2H@2H
3
During test, There will not been appeared
signal disconnection or interruption
between DUT and AP.
Discharge voltage: 1kV
10-12
ESD
C: 150pF
Discharge resistance330Ω
3
The products can recoverable smoothly
after ESD test.
Positive10 times
1 time for each second