EnvironmentalandLocationConsiderations
DonotmountTagExciterdirectlyonmetalsuchaselevatorcars.Use½inchnylonorplastic
spacersbetweentheTagExciterandthemetalsurface.MountingtheTagexciterdirectlyon
metalwilldetunethetransmittingantennas.
DonotmountTagExciterinalocationwherethereismetalbetweentheTagExciterandthe
intendedtagdetectionareasuchasontopofanelevatorcarorbehindametaldoor.RFdoes
notpropagatewellthroughthemetal,causingthetagtonotsee
theexciterfield.
Considertrafficpatternsandlegitimate/acceptabletaglocationswheninstallingtheTagExciter.
Asanexample,thebestlocation(shownbelow)createsatagexciterfieldindire ctproximityof
theprotecteddoor,whileatthesametimemaintainsasuitabledistancefromtheunprotected
doorsandroomsadjacentto
thestairwellwheretagsareallowedtobelocated.
Metal
Tag
TagExciter