Installation Instructions
PX/QX/RX Version 4.30 Installation Manual – Issue C
- 23 -
4 Input Concentrator
XiB Bus
OFF
Case
Tamper
Outputs 1 &2
current limited to
250 mA
OP2
OP1
PC1480
Address DIL Switch
7 6 5 4 3 2 1
1 0 0 0 0 0 0 0
2 0 0 0 0 0 0 1
3 0 0 0 0 0 1 0
4 0 0 0 0 0 1 1
5 0 0 0 0 1 0 0
6 0 0 0 0 1 0 1
7 0 0 0 0 1 1 0
8 0 0 0 0 1 1 1
9 0 0 0 1 0 0 0
10 0 0 0 1 0 0 1
11 0 0 0 1 0 1 0
12 0 0 0 1 0 1 1
13 0 0 0 1 1 0 0
14 0 0 0 1 1 0 1
15 0 0 0 1 1 1 0
16 0 0 0 1 1 1 1
17 0 0 1 0 0 0 0
18 0 0 1 0 0 0 1
19 0 0 1 0 0 1 0
20 0 0 1 0 0 1 1
21 0 0 1 0 1 0 0
22 0 0 1 0 1 0 1
23 0 0 1 0 1 1 0
24 0 0 1 0 1 1 1
25 0 0 1 1 0 0 0
26 0 0 1 1 0 0 1
27 0 0 1 1 0 1 0
28 0 0 1 1 0 1 1
29 0 0 1 1 1 0 0
30 0 0 1 1 1 0 1
31 0 0 1 1 1 1 0
32 0 0 1 1 1 1 1
33 0 1 0 0 0 0 0
34 0 1 0 0 0 0 1
35 0 1 0 0 0 1 0
36 0 1 0 0 0 1 1
37 0 1 0 0 1 0 0
38 0 1 0 0 1 0 1
39 0 1 0 0 1 1 0
40 0 1 0 0 1 1 1
41 0 1 0 1 0 0 0
42 0 1 0 1 0 0 1
43 0 1 0 1 0 1 0
44 0 1 0 1 0 1 1
45 0 1 0 1 1 0 0
46 0 1 0 1 1 0 1
47 0 1 0 1 1 1 0
48 0 1 0 1 1 1 1
49 0 1 1 0 0 0 0
50 0 1 1 0 0 0 1
51 0 1 1 0 0 1 0
52 0 1 1 0 0 1 1
53 0 1 1 0 1 0 0
54 0 1 1 0 1 0 1
55 0 1 1 0 1 1 0
56 0 1 1 0 1 1 1
57 0 1 1 1 0 0 0
58 0 1 1 1 0 0 1
59 0 1 1 1 0 1 0
60 0 1 1 1 0 1 1
61 0 1 1 1 1 0 0
62 0 1 1 1 1 0 1
63 0 1 1 1 1 1 0
64 0 1 1 1 1 1 1
Cct 4
Cct 3
C
8K2
8K2
ALARM
TAMPER
8K2
8K2
Cct 2
Cct 1
C
TAMPER
ALARM
ON
ADDRESS
81
+ - A B
Address DIL Switch
7 6 5 4 3 2 1
65 1 0 0 0 0 0 0
66 1 0 0 0 0 0 1
67 1 0 0 0 0 1 0
68 1 0 0 0 0 1 1
69 1 0 0 0 1 0 0
70 1 0 0 0 1 0 1
71 1 0 0 0 1 1 0
72 1 0 0 0 1 1 1
73 1 0 0 1 0 0 0
74 1 0 0 1 0 0 1
75 1 0 0 1 0 1 0
76 1 0 0 1 0 1 1
77 1 0 0 1 1 0 0
78 1 0 0 1 1 0 1
79 1 0 0 1 1 1 0
80 1 0 0 1 1 1 1
81 1 0 1 0 0 0 0
82 1 0 1 0 0 0 1
83 1 0 1 0 0 1 0
84 1 0 1 0 0 1 1
85 1 0 1 0 1 0 0
86 1 0 1 0 1 0 1
87 1 0 1 0 1 1 0
88 1 0 1 0 1 1 1
89 1 0 1 1 0 0 0
90 1 0 1 1 0 0 1
91 1 0 1 1 0 1 0
92 1 0 1 1 0 1 1
93 1 0 1 1 1 0 0
94 1 0 1 1 1 0 1
95 1 0 1 1 1 1 0
96 1 0 1 1 1 1 1
97 1 1 0 0 0 0 0
98 1 1 0 0 0 0 1
99 1 1 0 0 0 1 0
100 1 1 0 0 0 1 1
101 1 1 0 0 1 0 0
102 1 1 0 0 1 0 1
103 1 1 0 0 1 1 0
104 1 1 0 0 1 1 1
105 1 1 0 1 0 0 0
106 1 1 0 1 0 0 1
107 1 1 0 1 0 1 0
108 1 1 0 1 0 1 1
109 1 1 0 1 1 0 0
110 1 1 0 1 1 0 1
111 1 1 0 1 1 1 0
112 1 1 0 1 1 1 1
113 1 1 1 0 0 0 0
114 1 1 1 0 0 0 1
115 1 1 1 0 0 1 0
116 1 1 1 0 0 1 1
117 1 1 1 0 1 0 0
118 1 1 1 0 1 0 1
119 1 1 1 0 1 1 0
120 1 1 1 0 1 1 1
121 1 1 1 1 0 0 0
122 1 1 1 1 0 0 1
123 1 1 1 1 0 1 0
124 1 1 1 1 0 1 1
125 1 1 1 1 1 0 0
126 1 1 1 1 1 0 1
127 1 1 1 1 1 1 0
128 1 1 1 1 1 1 1
XiB
Status
DIL SW8 ON =
Tamper disable
+
-
All 4 circuit inputs are fast inputs
and can be programmed to allow
a direct connection of an inertia
sensor (refer to the engineer
manual for details.)