Installation Instructions

PX/QX/RX Version 4.30 Installation Manual – Issue C
- 33 -
Access Module
Brown, LED green
8K2
8K2
Alarm
Tamper
8K2
8K2
Alarm
Tamper
+ - A B
Engineer
Keypad
FS 1
FS 2
5 V
250 mA
8
1
ON OFF
+ - A B
XiB Bus
Black, 0 Volt
Orange, DATA 0/Clock
Blue, DATA 1/Data
Green, LED red
Red, V+ via FS1 (see LK 1)
Ground
Black, 0 Volt
Orange, DATA 0/Clock
Blue, DATA 1/Data
Green, LED red
Brown, LED green
Red, V+ via FS2 (see LK 1)
Door
(N.C.)
RTE
(N.O.)
NVM1
NVM2
12 V
250 mA
Door
Relay
(8A)
AUX
Relay
(2A)
Exit Reader
Entry Reader
Smart PSU
Interface
XiB
Comms
Case
Tamper
Address DIL Switch
5 4 3 2 1
1 0 0 0 0 0
2 0 0 0 0 1
3 0 0 0 1 0
4 0 0 0 1 1
5 0 0 1 0 0
6 0 0 1 0 1
7 0 0 1 1 0
8 0 0 1 1 1
9 0 1 0 0 0
10 0 1 0 0 1
11 0 1 0 1 0
12 0 1 0 1 1
13 0 1 1 0 0
14 0 1 1 0 1
15 0 1 1 1 0
16 0 1 1 1 1
17 1 0 0 0 0
18 1 0 0 0 1
19 1 0 0 1 0
20 1 0 0 1 1
21 1 0 1 0 0
22 1 0 1 0 1
23 1 0 1 1 0
24 1 0 1 1 1
25 1 1 0 0 0
26 1 1 0 0 1
27 1 1 0 1 0
28 1 1 0 1 1
29 1 1 1 0 0
30 1 1 1 0 1
31 1 1 1 1 0
32 1 1 1 1 1
DIL SW 8 - Tamper Disable
DIL SW7 - Default config
DIL SW6 - Not used
Reader supply voltage
- Select 12v for
Guardall readers.
To default the access module
configuration power up with SW7
ON and return SW7 to the Off
after a few seconds.