Installation Instructions
PX/QX/RX Version 4.30 Installation Manual – Issue C
- 34 -
Proximity Reader
The Proximity Reader is in compliance with the essential requirements and other relevant
provisions of Directive 1999/5/EC. Whilst it operates on a non-harmonised frequency of
125KHz, it meets all relevant harmonised standards. It has been notified in the following EU
countries: Belgium, Italy, France, The Netherlands, Denmark, Finland, UK, Ireland,
Germany, Spain, Portugal, Norway, Greece and Sweden.
Proximity Reader
Access Module Connections
Max. 150m
Brown, LED green
+ - A B
Engineer
Keypad
FS 1
FS 2
5 V
250 mA
8
1
ON OFF
+ - A B
Black, 0 Volt
Orange, DATA 0/Clock
Blue, DATA 1/Data
Green, LED red
Red, V+ via FS1 (see LK 1)
Ground
Black, 0 Volt
Orange, DATA 0/Clock
Blue, DATA 1/Data
Green, LED red
Brown, LED green
Red, V+ via FS2 (see LK 1)
NVM1
NVM2
12 V
250 mA
Exit Reader
Entry Reader
Smart PSU
Interface
XiB
Comms
Case
Tamper
Reader supply voltage
- Select 12v for
Guardall readers.
The diagram shows a Guardall reader.
Other types of reader may be used.
Refer to the engineer programming
manual (System/card types) for details.