Installation Instructions
PX Version 5.0 - QX/RX Version 4.51 Installation Manual – Issue F
- 30 -
Output Module
+
-AB
Engineer
keypad
+-
AUX
tamper contact
LE
D
1
6
ON OFF
TXoutputs
8
7
6
5
4
3
2
1
C
N
C
NO
C
N
C
NO
C
N
C
NO
C
N
C
NO
Output 8
Output 7
Output 6
Output 5
Not used
+
-
A
B
XiB Bus
C
N
C
NO
C
N
C
NO
C
N
C
NO
C
N
C
NO
Output 1
Output 4
Output 3
Output 2
Not used
820R
v+
10K
2.5A
The 10k pull up is
reduced to approximately
500R if a relay is fitted to
the same output channel.
Connect to control
panel XiB bus
Address DIL Switch
5 4 3 2 1
1 0 0 0 0 0
2 0 0 0 0 1
3 0 0 0 1 0
4 0 0 0 1 1
5 0 0 1 0 0
6 0 0 1 0 1
7 0 0 1 1 0
8 0 0 1 1 1
9 0 1 0 0 0
10 0 1 0 0 1
11 0 1 0 1 0
12 0 1 0 1 1
13 0 1 1 0 0
14 0 1 1 0 1
15 0 1 1 1 0
16 0 1 1 1 1
17 1 0 0 0 0
18 1 0 0 0 1
19 1 0 0 1 0
20 1 0 0 1 1
21 1 0 1 0 0
22 1 0 1 0 1
23 1 0 1 1 0
24 1 0 1 1 1
25 1 1 0 0 0
26 1 1 0 0 1
27 1 1 0 1 0
28 1 1 0 1 1
29 1 1 1 0 0
30 1 1 1 0 1
31 1 1 1 1 0
32 1 1 1 1 1
DIL SW6 - tamper
disable
Note: From firmware version 2.00B the address range
is reduced to 32 and DIL SW6 is tamper disable.