Installation Instructions

PX Version 5.0 - QX/RX Version 4.51 Installation Manual – Issue F
- 44 -
LEDs
Function Colour State Meaning
XiB Comms Green OFF No power
ON Communication error
Slow FLASH Operating normally
Quick FLASH Active
Hook Red ON Line seized
Line monitor Green ON Valid Exchange voltage level present
GSM Status Yellow Quick flash Network search
Slow flash Registered
ON Active call
Reporting Formats
The available reporting formats for each route is shown in the table.
Formats Route
PSTN GSM (audio) GSM (data)
Contact ID
ADEMCO Fast/Superfast Format
SIA Level 3
CESA (French panel variants only)
Speech (if optional module fitted,
v3.21 or later)
Audio (if optional module fitted)
PS/2 (GSR) - 1200 baud
PS/2 (GSR) - 9600 baud
SMS (v4.00 or later)
DIL Switches
To enable the Dual Comm module to be used with existing panels, the primary and secondary
communicator routes are selected by DIL switch 5. DIL switches 1-4 are reserved for future use.
DIL Switch
5 4 3 2 1
Function
0 0 0 0 0 PSTN is
p
rimar
y
route
1 0 0 0 0 GSM is primary route
The primary route is the normal route for all calls.
If the primary route is PSTN then;
All calls in all formats will be routed over the PSTN network
If there is a PSTN line fault then all calls will be routed over the GSM network (refer to the
reporting formats table for details)
Note: If the call format is PS/2 and there is a PSTN line fault then the call will be made on the same
number of GSM. This call will fail as the Windsor modem and GSM modem will use different
telephone numbers.
If the primary route is GSM then;
All calls in all formats will be routed over the GSM network
If there is no GSM service available then all calls will be routed over the PSTN network (refer
to the reporting formats table for details)