Product Name: 2-Way Standing Seam Roof Clamp Part #: 10600 Instruction Manual Do not throw away these instructions! Read and understand these instructions before using equipment! Introduction 1 Applicable Safety Standards 1 Worker Classifications 1 Product Specific Applications 1-2 Limitations 2-3 Components and Specifications 3 Installation and Use 4 Maintenance, Cleaning, and Storage 5 Inspection 5 Inspection Log 5 Safety Information 6 Labels 7
Serial #: Trainer: User: Applicable Safety Standards When used according to instruction specifications, this product meets or exceeds all applicable OSHA 1926 Subpart M, OSHA 1910, ANSI Z359.1-2007, and ANSI A10.32-2012 standards for fall protection. Applicable standards and regulations depend on the type of work being done, and also might include state-specific regulations. Consult regulatory agencies for more information on personal fall arrest systems and associated components.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 6305 S. 231st St., Kent, WA 98032 Guardian Fall Protection Restraint: 2-Way Standing Seam Roof Clamp may be used in Restraint applications. Restraint systems prevent workers from reaching the leading edge of a fall hazard. Always account for fully deployed length of lanyard/SRL. Structure must withstand loads applied in the directions permitted by the system of at least 1,000 lbs. No free fall is permitted.
Correct Anchorage Positioning: This chart details allowable working zones required to reduce risk of swing falls and improper side loading. ALWAYS adhere to information specified by chart.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 Installation and Use Prior to installation, plan your system: 1. All PFAS equipment must be selected and deemed compatible with 2-Way Standing Seam Roof Clamp by a Competent Person. 2. Eliminate or minimize all risk of swing fall hazards. 3. Ensure installation location and work surface are free of all damage, including, but not limited to, corrosion, rot, rust ,debris, and sharp or abrasive edges and surfaces.
When not in use, store equipment where it will not be affected by heat, light, excessive moisture, chemicals, or other degrading elements. Inspection Prior to EACH use, inspect 2-Way Standing Seam Roof Clamp for deficiencies, including, but not limited to, corrosion, deformation, pits, burrs, rough surfaces, sharp edges, cracking, rust, paint buildup, excessive heating, alteration, and missing or illegible labels.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 6305 S. 231st St., Kent, WA 98032 Guardian Fall Protection Safety Information ! WARNING Failure to understand and comply with safety regulations may result in serious injury or death. Regulations included herein are not all-inclusive, are for reference only, and are not intended to replace a Competent Person’s judgment or knowledge of federal or state standards. Do not alter equipment. Do not misuse equipment.
www.guardianfall.com Labels Date of Manufacture: Part # 10600 90130 (Rev. B) Made in China 6305 S. 231st St., Kent, WA 98032 • 800-466-6385 • www.guardianfall.com INSPECTION GRID User must inspect prior to EACH use. Competent Person must complete formal inspection every 6 months. Competent Person to inspect and initial. Date of First Use: __________________. Product lifetime is indefinite as long as equipment passes pre-use and Competent Person inspections.