Product Name: Standing Seam Roof Clamp Part #: 00250 Instruction Manual Do not throw away these instructions! Read and understand these instructions before using equipment! Introduction 1 Applicable Safety Standards 1 Worker Classifications 1 Product Specific Applications 1-2 Limitations 2-3 Components and Specifications 4 Installation and Use 4-5 Maintenance, Cleaning, and Storage 5 Inspection 6 Inspection Log 6 Safety Information 6-7 Labels 7
Serial #: Trainer: User: Applicable Safety Standards When used according to instruction specifications, this product meets or exceeds all applicable OSHA 1926 Subpart M, OSHA 1910, ANSI Z359.1-2007, and ANSI A10.32-2012 standards for fall protection. Applicable standards and regulations depend on the type of work being done, and also might include state-specific regulations. Consult regulatory agencies for more information on personal fall arrest systems and associated components.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 6305 S. 231st St., Kent, WA 98032 Guardian Fall Protection Restraint: Standing Seam Roof Clamp may be used in Restraint applications. Restraint systems prevent workers from reaching leading edge of fall hazard. Always account for fully deployed length of SRL. Structure must withstand loads applied in the directions permitted by the system of at least 1,000 lbs. No free fall is permitted.
www.guardianfall.
www.guardianfall.com Components and Specifications Materials: powder-coated and galvanized steel. Carriage SRL (sold separately) Hitch Pin Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 Pivoting Stanchion Telescoping Tubing Roof Clamp x1 per side (L/R) L R Bolt Stop Clevis Pin ! WARNING Mounting Bolts x2 per side (L/R) Prior to installation, a Qualified Person must determine Standing Seam Roof Clamp is compatible with roof seam.
www.guardianfall.com 3. Place Roof Clamp around roof seams. Ensure that bent side of each clamp is underneath the lip of each respective metal roof seam. Flat sides of Roof Clamps MUST be flush with flat sides of roof seams. 4. Tighten all Mounting Bolts to secure Standing Seam Roof Clamp to metal roof. ALL Mounting Bolts MUST be torqued to 50 foot-pounds. 5. Prior to EACH use, re-torque all Mounting Bolts to 50 foot-pounds. ! WARNING It is critical to properly torque Mounting Bolts.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 6305 S. 231st St., Kent, WA 98032 Guardian Fall Protection Inspection Prior to EACH use, inspect Standing Seam Roof Clamp for deficiencies, including, but not limited to, corrosion, deformation, pits, burrs, rough surfaces, sharp edges, cracking, rust, paint buildup, excessive heating, alteration, and missing or illegible labels.
Harnesses and connectors selected must be compliant with manufacturer’s instructions, and must be of compatible size and configuration. Snap hooks, carabiners, and other connectors must be selected and applied in a compatible fashion. All risk of disengagement must be eliminated. All snap hooks and carabiners must be self-locking and self-closing, and must never be connected to each other. A pre-planned rescue procedure in the case of a fall is required. The rescue plan must be project-specific.