User Manual
5. Reinstall the Pre-filter Screen by inserting into the tabs
on the body of the unit.
Note: The 2 center tabs on the screen should face outwards, and
the arrows located on the side should point up.
6. Return the front panel: First insert the front panel bottom hooks then close the front panel.
Make sure the magnetic closure is secure.
N
ote: Proper filter and front panel installation is necessary for unit to turn on.
RESET INDICATOR LIGHT
After the filter OR UV-C bulb has been replaced you will need to reset the
indicator light.
1. The reset button is located IN the side grill (See INSET)
2. To reset the light, use a paper clip or flat tipped object, insert
it into the lower left portion of the grill and push the red button
with the tip.
3. Check to make sure light is off when unit is restarted.
E-8 E-9
2. Gently pull the top of
the front panel and lift
from base.
3. Remove the filters by
pulling the side tabs.
4. Insert the new filters into the uni
t
– consult the arrows on the filters
for correct installation direction.
The proper installation
sequence should be
1. Carbon Filter
2. Filter
FILTER REPLACEMENT
The “Replace Filter” indicator will light when it is time to replace your filter. Depending on usage
and environmental conditions the filters will last approximately 6 months and should be replaced at
the same time. The filter will turn from white to gray/black when it is dirty and needs replacing. It is
important to maintain and change the filters to continue to optimize the performance of the air
purifier.
IMPORTANT: DO NOT wash and re-use the filters. Please contact Customer Service at
1.866.603.5900 or visit us at www.guardiantechnologies.com to purchase a
replacement filter.
REMOVE AND REPLACE FILTER
1. Turn off and unplug the unit.
1. Pull and remove the front
cover and all filters.
2. After removing the filters, use a Philips head
screwdriver to remove 2 screws and detach the
UV-C Shield.
3. The UV-C Bulb is removed by carefully grasping the bulb with a clean cloth or tissue and twisting
the bulb 1/4 turn. Remove from unit.
4. The UV-C Bulb is reinstalled by reversing the process in Step 3.
5. Re-attach the UV-C Shield.
6. Reset the UV light according to the "Reset Indicator Light" instructions (E8).
Bulb is NOT visible until the
UV-C SHIELD has been
removed.
REPLACEMENT BULB: LB9200
AVAILABLE AT 866.603.5900 OR WWW.GUARDIANTECHNOLOGIES.COM
IMPORTANT: The UV-C Bulb should be replaced every 10 - 12 months depending on use.
Please contact Customer Service at 1.866.603.5900 or visit us at
www.guardiantechnologies.com to purchase a replacement bulb.
TWIST BULB 1/4 TURN
TO REMOVE BULB
INSTALLING & REMOVING UV-C BULB
UV Bulb Replacement Indicator: The UV light on the display will flash when its
time to replace the UV bulb.