Contents Default Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . …………… 1 Menu Navigation Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . …………… 1 Text Entry Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ……………. 1 Operator Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ……….. 2 User Set-up . . . . . . . . . . . . . . . . . .
Contents Door Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. ..16 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 16 Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ... 16 Timers . . . . . …. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 Timed Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
ACT1000/2000 Operating Instructions Software Version 3.23-00 Operating Instructions for ACT1000/2000 Access Control Units Software Version: 3.23-00 All user functions are accessed via two six-digit codes. The first code is for the Operator who is responsible for the day-to-day administration of the system, adding and deleting users, setting names and assigning time-zones etc.
ACT1000/2000 Operating Instructions Software Version 3.23-00 Operator Menu User Setup Enable Disable Assign Names Assign Groups Assign Options Assign PINs Learn Batch Cards One-To-One Card Validity2 Allow a user or range of users to open the door Prevent a user or range of users from opening the door Enter a name for each user Assign users to groups Specify options for each user Set the individual PIN for each user Learn randomly coded cards (e.g.
ACT1000/2000 Operating Instructions Software Version 3.23-00 User Setup The User Setup menu allows the operator to enable and disable individual users, and to change the configuration information for each user. In each of the user setup functions, the user is selected by either using the 0 key to advance to the required user, or alternatively by using the numeric keys 1-9 to directly enter the number of the desired user.
ACT1000/2000 Operating Instructions Software Version 3.23-00 Assign PINs The Assign PINs function allows a different PIN to be assigned to each of the first 1000/2000 users. Initially, the PIN will be unset. Pressing the ✔ key will prompt for the PIN for the displayed user to be entered (it will not be displayed). The PIN must then be reentered for verification. The PIN will be accepted as long as it does not conflict with any existing PIN (or duress PIN). Entering all zeros will delete the PIN.
ACT1000/2000 Operating Instructions Software Version 3.23-00 One-To-One In One-To-One Mode, any known card may be assigned to any of the first 1000/2000 users. If the site code and card number are known then they may be entered in from the keypad or the card may also be presented to a reader (similar to Learn Mode). Card Validity (ACT 2000 Only) The Card Validity menu allows any of the first 2000 users to be assigned a validity period.
ACT1000/2000 Operating Instructions Software Version 3.
ACT1000/2000 Operating Instructions Software Version 3.23-00 Display Log The Display Log function allows the operator to view events in the historical log directly on the LCD display. When this option is selected, the latest event in the log is displayed with the time and date on the top line of the display, and the event details being scrolled across the bottom line. Each log event will be displayed in turn (stepping backwards in time) until the end of the log is reached.
ACT1000/2000 Operating Instructions Software Version 3.23-00 Control Door The Control Door menu allows the operator to control the door or externally connected equipment such as lighting or heating. Lock Door The Lock Door function causes the door relay to be de-energized. The bottom line of the display will show “Door Locked” and the red LED on the reader will flash. All subsequent cards will be rejected until the door is unlocked or returned to its normal state.
ACT1000/2000 Operating Instructions Software Version 3.23-00 Clear All (ACT2000 Only) This function manually removes all users from the area. An event is logged for tracking. This is typically used at the end of a day or week to remove any users from the system who have neglected to use their cards when exiting. Set Date/Time The Set Date/Time function allows the operator to adjust the date and time on the controller’s real-time clock.
ACT1000/2000 Operating Instructions 1) Select Timezone Software Version 3.
ACT1000/2000 Operating Instructions Software Version 3.23-00 Issue Number This option allows the user to set the current system issue level to a number between zero (default) and 255. Only cards that have an issue number greater than or equal to the system issue level will be granted access. A card without an issue number encoded (Proximity, Wiegand, etc.) has an effective issue level of zero. Issue numbering is intended for use in situations where all cards on the system are replaced on a regular basis.
ACT1000/2000 Operating Instructions Software Version 3.23-00 Installer Menu System Settings Operation PIN Only Learn Ext. Keypad1 KPD Release1 Exit PIN’s Second Door1 User Limiting2 One-To-One Multiple Display Door Settings* Backlight Keypad Beep Show Status Show Events Handshake Tech Bleep2 PIN’s alone are used to gain access Users 1-1/2000 may use random coded cards Use external ACT20 keypad ✔ Key is exit button.
ACT1000/2000 Operating Instructions Door Settings* (contd.) Communications Software Version 3.
ACT1000/2000 Operating Instructions Software Version 3.23-00 System Settings The System Settings menu allows the installer to access a number of different configuration menus controlling different aspects of the setup of the controller. Pressing the ✔ key toggles the setting of a displayed option. Operation This menu allows the installer to select or de-select a number of options relating to the default operation of the controller.
ACT1000/2000 Operating Instructions Software Version 3.23-00 Fire Doors This function allows a group of doors (or all doors) to be configured for fire override. A 0Volt signal from a fire alarm (or other) system is applied to the AUX input on door 1. This maintains normal operation. When the 0Volt signal is removed, the selected doors are held open until the 0Volt signal is re-applied.
ACT1000/2000 Operating Instructions Software Version 3.23-00 Door Settings The Door Settings menu allows the installer to access a number of different configuration menus controlling different aspects of the selected door. The door for which the settings are to be changed is first selected using the 0 key, then the ✔ key is pressed to enter the menu. The 0 key is used to select the required option or setting which is changed using the ✔ key.
ACT1000/2000 Operating Instructions Software Version 3.23-00 Timers The door timers menu allows the installer to program the time delays for the relay, AUX output, open collector outputs OP2 and OP3 and the door ajar alarm time. Each timer may be programmed with a duration from 1 to 999 seconds. The relay time may be programmed to 0 seconds, which will operate the relay for a quarter of a second approximately. This can be used for turnstile applications.
ACT1000/2000 Operating Instructions Software Version 3.23-00 High Speed Communications on the controller defaults to 9600 baud. The high speed option sets the controller to operate at 19200 baud. This option applies to direct connect to a PC, networked interface and printer modes of operation. Slave Mode (ACT2000 Only) This option selects slave mode operation as part of an ACT5000pc network.
ACT1000/2000 Operating Instructions Software Version 3.23-00 Site Code 1 This function allows the 8-digit site primary code for the system to be entered. The controller will recognize only cards with a matching site code. This code should also be quoted whenever additional cards or tags are being ordered for this installation. The factory default site-code is 10-2770-09, which allows the use of the test card supplied with the controller.
Typical ACT1000 Configuration (Standalone) Timekeeper Lithium Battery NETWORK PRINTER Card or Proximity Reader CARD/PROX READER SENSE CLOCK DATA +5V 0V RED GREEN A B 0V TX RX Door Contact PUSH BUTTON DOOR CONTACT INTER LOCK 0V OP2 OP3 BUZZER TAMPER BATCH: 96XX-1 PRODUCT: ACT 1000 REV1.
Typical ACT2000 Configuration (Standalone) NETWORK B 0V A CR2032 Card/Proximity or Pin Reader - Door 1 + DOORS A B 0V SERIAL/PRINTER DTR RX TX SENSE GREEN CLOCK RED 0V +5V +5V 0V DATA RED CLOCK GREEN SENSE BATCH: Release Button Door 1 PRODUCT: ENTRY/EXIT READER 2 ENTRY/EXIT READER 1 0V DATA Card/Proximity or Pin Reader - Door 2 Door 2 Release Button 98XX-1 ACT2000 REV2.
DS100 Door Station Installation ACT 2000 NETWORK Network cable is single shielded twisted pair, Belden 9501 or similar Door Contact A B 0V Shield To next door Shield DTR Serial DOOR I/O B A B A Total Length max 1.
Wiring for Entry/Exit Readers Card / Proximity or Pin Reader (Entry) 1 2 3 4 5 6 7 8 9 Controller 0 Card or Proximity Reader (Exit) Card/Prox Reader SENSE CLOCK DATA +5V 0V RED GREEN The above diagram is valid only for clock-and-data type readers. Wiring for Clock and Data / Wiegand Reader Wire both readers in parallel but leave the SENSE line on the Exit reader unconnected. For Wiegand Exit readers Connect DATA 0 of the exit reader to SENSE on the controller.
ACT20 PIN Pad Installation Diagram + - 12-24V AC/DC ORANGE BL AC K ELL BR OW OW N ITE OP3 WH E BLU OP2 EE N GR 98XX-1 ACT20 REV2.1 012345 0 1 2 3 4 5 6 7 8 9 The ACT20 connects in parallel between the reader and the controller. An extra line (ORANGE) is used to bring +12VDC power to the ACT20. The shields should be joined.
ACT1000/2000 Cable Connections Direct Connection Cable (PC to Controller) 2 3 7 DB25 Female (Rear View) ACT 1000/2000 3 Way Pluggable 1 2 3 4 5 DB9 Female (Rear View) 0V 6 7 8 9 TX RX Max cable length is 5m using standard alarm cable or 30m using twin twisted-pair (use 0V in each pair) Serial Printer Cable DB25 Male (Rear View) 7 3 ACT 1000/2000 3 Way Pluggable 0V 20 TX RX Max cable length is 5m using standard alarm cable or 30m using twin twisted-pair (use 0V in each pair) Serial Modem Cable
Interlock Configuration GENERAL I/O When Interlock is enabled on a door, the door is locked when the AUX input is active. When the door is open, OP3 is active.
ACTWinPro Configuration NETWORK A B 0V Direct Connect Cable 0V RX TX 0V GREEN SERIAL/PRINTER DTR DOORS A B ACTWinPro From the Installer Menu, do the following: 1. Factory Default the controller. 2. Go to the Communications menu and Set Address. If there is only 1 controller, set the address to 1. For more than 1, assign each controller a unique address, starting at 1. RED ACT2000 3. Set Direct Connect to Yes if the PC is connected directly to one controller (as shown above).
ACT 4-Line Network Wiring ACT 4-Line Nework Interface Card RS485 232 Interface RS485 Converter To PC SCN C DI DO RS232 PORT Connections for 9 Way Connector of PC SCN = Pin 5 C = Pin 7 DI = Pin 3 D0 = Pin 2 LED2 L E N To Mains Supply LED3 Line 2 Line 3 Line 4 C12 C12 C12 C12 Network cable is single shielded twisted pair, Belden 9501 or similar C = SHIELD 1= B 2= A All lines are equivalent and operate in parallel Any controller may be connected to any line.
ACT Single Line RS-485 Converter 0V Function 1 2 3 4 +12V 0V & Shield B A BAUDRATE SELECT 9600 Pin RS-232 19200 +12V 4 3 2 1 12V DC Power Supply (300mA) ACTWin Software RS-485 Bus Network cable is single shielded twisted pair: Belden 9501 or similar ACT 2000 ACT 1000 RS485 line may be up to 1km in length and connect up to 32 controllers Timekeeper Lithium Battery A B 0V TX RX NETWORK PRINTER DTR RX TX 0V DOORS SERIAL/PRINTER A B 0V A B 0V NETWORK PRINTER NETWORK Timekeeper Lithium
ACT Modem Configuration Direct Connection from Modem to Controller NETWORK A B 0V Connections for 25 Way male Connector DOORS A B 0V RX TX 0V 1. Connect Modem Cable directly to ACT1000/2000 and Modem SERIAL/PRINTER DTR RX = Pin 3 TX = Pin 2 0V = Pin 7 2. In Communications Menu Set: 7 32 Address = 1 Direct Conn = Y DB25 Male (Rear View) ACT 2000 3.
ACTLAN Configuration Diagram link net Tx/Rx collision diagnositc status serial 10BASE-T 9-30v LAN/WAN Connections for 25 Way male Connector 7 32 DB25 Male (Rear View) Max cable length is 5m using standard alarm cable or 30m using twin twisted-pair (use 0V in each pair) Connections for Direct Connect Connections for Network 1. Connect cable to ACT Network card 1. Connect cable directly to and LAN Interface ACT1000/2000 and LAN device NETWORK A ACTWinPro Software B 0V 2.
ACT System Diagram ACTWinPro PC ACTWinPro PC RS232 LAN RS232 Modem ACT 2000 Door 1 ACTLAN Door 2 PSTN DS100 DS100 Door 3 Door 4 DS100 Door 1 ACT 2000 Door 16 Door 2 4 Line Interface Modem RS485 Line 4 RS485 Line 3 RS485 Line 2 485 Converter RS232 RS485 Line 1 (Max length 1.