User manual
 ACT1000/2000 Operating Instructions Software Version 3.23-00 
Page 18 of 32 
High Speed 
Communications on the controller defaults to 9600 baud. The high speed option sets the 
controller to operate at 19200 baud. This option applies to direct connect to a PC, networked 
interface and printer modes of operation. 
Slave Mode (ACT2000 Only) 
This option selects slave mode operation as part of an ACT5000pc network. While the 
controller is switched into slave mode and all card events are transmitted to the network 
master for validation. The controller itself will not make any decisions on card events unless 
it is operating in fallback mode due to a network failure. This option is always set to No 
when using ACTWinPro.
No Hist. Log 
This option suppresses the reporting of events occurring while offline in slave mode only. 
Normally when the controller is operating in slave mode, events are logged locally if the 
controller is offline, and are transmitted to the PC when communications are restored.
Print All 
This option selects real-time printing to an attached serial printer. Each event is time stamped 
and printed immediately on the printer. Real-time printing will be temporarily suspended 
while a full log printout requested from the operator menu is in progress. 
Remote Doors (ACT2000 Only) 
This menu is where additional door stations or ACT1000 units are configured as extra doors 
on the ACT2000 controller. The new door (Door 3 to 16) is selected using the 0 key and the 
current status of the door is displayed on the bottom line of the LCD. The ✔ 
✔ ✔ 
✔ key may then be 
used to enable or disable the door: 
1) To enable, select a 
Door 3  0 for next door 
 Disabled door 
Disabled 
✔
✔✔
✔ to enable door 
2) To disable, select an 
Door 3  0 for next door 
 Enabled door 
Door Normal 
✔
✔✔
✔ to disable door 
If a non-existent or incorrectly addressed door is enabled, the door will be polled for a short 
while, then the status will be displayed as Door Offline. 
Set Password 
A password consisting of a 10 digit number may be programmed into the controller to 
prevent unauthorized access from remote ACTWinPro users. Ensure this password matches 
the encryption key used by ACTWinPro. 
Card Setup 
The card setup menu is used to inform the controller which cards should be recognized by the 
system. Usually all that is required is to set the primary site code for the system. The site 
code is supplied along with any cards ordered, or can be obtained directly from ACT. In 
addition, a site code from another installation may be entered allowing shared access to the 
building. Where non-standard cards are being used, possibly from a previous access control 
or time & attendance system, the card format may be altered to accept these. 