Product Manual

MODEL NUMBER:
DATE OF MANUFACTURE:
INSPECTION AND MAINTENANCE LOG
Date Part Number Comments Inspector Name
MAX ARREST FORCE 1800 LBF (40.6 KG) BREAKING STRENGTH 5000 LBF (22.2 KN)
INSPECTION:
Inspection required prior to each use and at least every 6 months by a Competent Person other than the
user. Competent Person inspections must be recorded in this instruction manual and on inspection grid on
product labeling.
1. Inspect Ground-Up Anchor for visible signs of damage or wear that could a ect operation.
For example: kinked of frayed cables.
2. Make sure all labeling is a xed to the unit..
3. Make sure the D-ring can rotate 360°.
4. Check spoons and end termination operate smoothly with no metal burrs.
5. Record inspection results in the space provide above.
*If any damage that could a ect the strength or operation of the device, or unsafe
conditions are found, proper disposal is required. The anchorage connector must be
rendered unusable and then properly discarded.
LABEL LOCATION