OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: 00237/00238 IMPORTANT!!! ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH. USERS SHOULD BE FAMILIAR WITH PERTINENT REGULATIONS GOVERNING THIS EQUIPMENT. ALL INDIVIDUALS WHO USE THIS PRODUCT MUST BE PROPERLY INSTRUCTED ON HOW TO USE THIS DEVICE. V3.
Read This Instruction Manual Carefully Before Using This Equipment. User Instructions must always be available to the user and are not to be removed except by the user of this equipment. For proper use, see supervisor, User Instructions, or contact the manufacturer. Compliant fall protection and emergency rescue systems help prevent serious injury during fall arrest. Users and purchasers of this equipment must read and understand the User Instructions provided for correct use and care of this product.
Model # 00237 Zinc Plated Steel For steel applications the steel flange must be at least 1/4” thick. Make sure the MEGA swivel rest entirely on the steel flange. UTS - 10,000-lbf / 44kN Model # 00238 Zinc Plated Steel Use in fully cured normal weight concrete with a compression strength of at least 3,000 PSI (20.7 MPa) UTS - 10,000-lbf / 44kN LABEL LOCATIONS WARNING: All persons using this equipment must read, understand and follow all instructions.
STEEL MOUNTING 5/8”-11 Lock Nut Torque Range: 75-90 ft-lbs (100-120Nm) * Use tapered washer with I-beams that have tapered flanges 5/8” Lock Washer drill 5/8” (16mm)Ø 5/8”-11x4” Hex Bolt * ) 6mm edge 3”(7rom any 1/4” (6mm) min min f * For steel applications a grade-5, 8 (or equivalent) bolt no shorter than 4” (100mm) with a locking nut and washer must be used. Swivel anchor must be flush with steel surface. A 16mm bolt may be used in place of a 5/8”-11 for metric applications.
WELD ON MOUNTING Grade - 5 or 8 bolt 5/8”-11 x 1-3/4” Internal Tooth Lock washer Torque Range: 75-90 ft-lbs (100-120Nm) * Weld 3/8” min (9.5mm) * Welding procedure must be approved by an Engineer or other qualified person to be compatible with any and all structural & operational characteristics of the selected installation location. BACK PLATE MOUNTING Back Plate to be used with 5/8” (16mm) bolts or all thread. Drill hole perpendicular into surface so bolt can pass freely through the substrate.
(ANCHOR POINT) WORK SURFACE *The structure the anchorage is attached to must be able to support 10,000-lbf (44kN) and installed under the supervision of a qualified person. WORK SURFACE *All products subjected to fall arresting forces should be removed from service immediately! MINIMUM CLEARANCE 3ft (1m) DECK/FLOOR/GROUND LEVEL WARNING!!! SWING FALLS CAN OCCUR WHEN THE WORKER IS NOT DIRECTLY UNDER ANCHOR POINT.
PART NUMBER KIT CONTENTS ACCESSORIES CONCRETE METAL 00231 (Steel Mounting Hardware Kit) + 00237 (Swivel with Steel Mounting kit) 00239 (Concrete Hardware Kit) + 00238 (Swivel with Concrete Mounting Kit) + 00251 (Weld-on Mounting Kit) 00234 (Backing Plate Only) For more information:
MAINTENANCE, CLEANING AND STORAGE Cleaning periodically will prolong the life and proper functioning of the product. The frequency of cleaning should be determined by inspection and by severity of the environment. Clean with compressed air and/or a stiff brush using plain water or a mild soap and water solution. Do not use any corrosive chemicals that could damage the product. Wipe all surfaces with a clean dry cloth and hang to dry, or use compressed air.