Item Brochure

Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
Halo Anchor
Materials: forged steel, zinc-plated steel, and rubber.
Compliant with all OSHA 1910, OSHA 1926 Subpart M,
ANSI Z359.1-2007, and ANSI A10.32-2012 regulations.
Halo Anchor is suitable for the following applications:
MAXIMUM 1 connection per Halo Anchor.
UPC-A Code: 672421004822
Custom configurations not available. Not repairable.
Contact customer service for details.
Personal Fall Arrest: Halo Anchors may be used to support a MAXIMUM
1 Personal Fall Arrest System (PFAS) for use in Fall Arrest applications.
Structure must withstand loads applied in the directions permitted by
the system of at least 5,000 lbs. Maximum free fall is 6‘, or up to 12’ if
used in combination with equipment explicitly certified for such use.
Applicable D-ring: Dorsal.
Restraint: Halo Anchors may be used in Restraint applications. Restraint
systems prevent workers from reaching the leading edge of a fall hazard.
Always account for fully deployed length of lanyard/SRL. Structure must
withstand loads applied in the directions permitted by the system of at
least 1,000 lbs. No free fall is permitted. Restraint systems may only be
used on surfaces with slopes up to 4/12 (vertical/horizontal). Applicable
D-rings: Dorsal, Chest, Side, Shoulder.
For all applications: worker weight capacity range
(including all clothing, tools, and equipment) is 130-420 lbs.
Work Positioning: Halo Anchors may be used in Work Positioning applications. Work Positioning systems allow
a worker to be supported while in suspension and work freely with both hands. Structure must withstand loads
applied in the directions permitted by the system of at least 3,000 lbs. Maximum allowable free fall is 2’.
Applicable D-rings: Side.
Minimum substrate thickness requirements:
Wood: 3/4” CDX or better.
Metal: 20 gauge or better.
Fasteners:
Wood: (6) 1/4” x 3” lag screws OR (12) 16d nails.
Metal: (6) 1/4” x 3” metal deck screws.
All fasteners must be fully embedded into substrate.
Suitable for use in horizontal lifeline (HLL) applications. All set-up, installation, and use of HLLs must
be done under the supervision of a Qualified Person.