Product Name: CB Anchor Series Part #: 00645; 00651; 00656; 00652; 00690; 00653; 00657; 10645; 10651; 10656; 10652; 45020; 10681; 10683; 00680; 00600; 00610; 10685 Instruction Manual Do not throw away these instructions! Read and understand these instructions before using equipment! Introduction 1 Applicable Safety Standards 1 Worker Classifications 1 Product Specific Applications 2 Limitations 2-3 Components and Specifications 4 Installation and Use 4-8 Maintenance, Cleaning, and Storage 9
Serial #: Trainer: User: Applicable Safety Standards When used according to instruction specifications, this product meets or exceeds all applicable OSHA 1926 Subpart M, OSHA 1910, ANSI Z359.1-2007, and ANSI A10.32-2012 standards for fall protection. Applicable standards and regulations depend on the type of work being done, and also might include state-specific regulations. Consult regulatory agencies for more information on personal fall arrest systems and associated components.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 6305 S. 231st St., Kent, WA 98032 Guardian Fall Protection Product Specific Applications ! WARNING Use of equipment in unintended applications may result in serious injury or death. Maximum 1 attachment per connection point. Personal Fall Arrest: CB Anchors may be used to support a MAXIMUM 1 personal fall arrest system (PFAS) for use in Fall Arrest applications.
Two connectors to same D-ring. NO. Connector directly to webbing. NO. Incompatible or irregular application, which may increase risk of roll-out. NO. Connector directly to horizontal lifeline. NO. Two or more snap hooks or carabiners connected to each other. NO. Correct Anchorage Positioning: This chart details allowable working zones required to reduce risk of swing falls and improper side loading. ALWAYS adhere to information specified by chart.
Materials: galvanized steel, stainless steel, or powder-coated steel. 6305 S. 231st St., Kent, WA 98032 Guardian Fall Protection Connection Point Fastener installation holes (x4) Connection Point Anchor Post Wood/metal fastener installation holes (x40 / x60) phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.
All fasteners fully embedded in substrate 1) Place CB Anchor at selected installation location; 2) Install all fasteners until snug, and ensure CB Anchor is fully secured to substrate; 3) All fasteners MUST be fully embedded in wood decking. 5/8” CDX *Sample profile shown only Metal Install: MINIMUM substrate requirement: 20 gauge, or 22 gauge if reinforced with CB Spanner Plate (part # 00604, contact Guardian for more information).
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 Installation, CB-18 (part #s 00652, 00656, and 00657) Wood Install: MINIMUM substrate requirement: 3/4” CDX. • CB-18 Fasteners: (60) #14-10 2” screws for wood decking. All fasteners fully embedded in substrate 1) Place CB Anchor at selected installation location; 2) Install all fasteners until snug, and ensure CB Anchor is fully secured to substrate; 3) All fasteners MUST be fully embedded in wood decking.
www.guardianfall.com DO NOT INSTALL S-ANCHOR (CB-24) ON WOOD SUBSTRATES. Metal Install: DO NOT INSTALL S-ANCHOR (CB-24) ON METAL DECKING. Installation onto structural metal beams is permitted (see backer plate install). Concrete Install: MINIMUM substrate requirement: 6” thick, 2,500 p.s.i. Installation must be done a MINIMUM 8“ from all edges. Hilti HIT-HY 200 epoxy or equivalent is required for installation of Hilti HIT-Z Rods.
www.guardianfall.com Concrete Install: MINIMUM substrate requirement: 6” thick, 2,500 p.s.i. Installation must be done a MINIMUM 8“ from all edges. Hilti HIT-HY 200 epoxy or equivalent is required for installation of Hilti HIT-Z Rods. 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 • CB-1-B Fasteners: (4) 1/2” Hilti HIT-Z Rods (or equivalent), with minimum 3--1/2“ embedment.
When not in use, store equipment where it will not be affected by heat, light, excessive moisture, chemicals, or other degrading elements. Inspection Prior to EACH use, inspect CB Anchor for deficiencies, including, but not limited to, corrosion, deformation, pits, burrs, rough surfaces, sharp edges, cracking, rust, paint buildup, excessive heating, alteration, and missing or illegible labels. IMMEDIATELY remove CB Anchor from service if defects or damage are found, or if exposed to forces of fall arrest.
www.guardianfall.com phone: (800) 466-6385 fax: (800) 670-7892 6305 S. 231st St., Kent, WA 98032 Guardian Fall Protection Safety Information ! WARNING Failure to understand and comply with safety regulations may result in serious injury or death. Regulations included herein are not all-inclusive, are for reference only, and are not intended to replace a Competent Person’s judgment or knowledge of federal or state standards. Do not alter equipment. Do not misuse equipment.
www.guardianfall.com Labels CB Anchor Series Prior to use, read and understand all manufacturer’s instructions provided with equipment at time of shipment. Only make compatible connections. Refer to instructions for proper installation and connection methods. 6305 S. 231st St. Kent, WA 98032 All PFAS equipment must be selected and deemed compatible with CB Anchor by a Competent Person. Capacity range: 130-310 lbs., or up to 420 lbs. if used with equipment explicitly certified for such use.