Installation:
1. Attach Guardrail Receiver to Swing Arm Plate with
Wing Nut and Bolt.
2. Remove Locking Pin, adjust Guardrail Receiver
so it is perpendicular to ground (not substrate), and
reinsert Locking Pin and secure with Locking Clasp.
3. Place Residential Guardrail System at installation
location. Residential Guardrail System must lie flush
with substrate.
4. Install (4) 16d nails OR (4) 2½” #10 Primeguard
screws through holes in Swing Arm Plate. Fasteners
must be fully embedded in substrate.
5. Repeat steps 1-4 for all Residential Guardrail
Systems.
6. Install Guardrail Posts in all Residential Guardrail
Systems. Guardrail Post rungs must face in towards
work surface.
7. Install guardrails in all Guardrail Post rungs.
Guardrails must be compatible snap-on metal rails,
or 2” x 4” or 2” x 6” construction grade lumber. If
using lumber guardrails, lap guardrails in a
continuous direction. Lumber guardrails must overlap
a minimum of 12” at each end between consecutive
Guardrail Posts. Secure toeboards with (1) 16d nail
at Toeboard Installation Location.
Guardrail Receiver adjusted
perpendicular to ground.