Datasheet
mail@gude.info
www.gude.info
Gude Analog- und Digitalsysteme GmbH
Eintrachtstr. 113
50668 Koeln, Germany
T +49.221.912 90 97
F +49.221.912 90 98
Radio Time Systems
EMC Professional 3001 / 3011
Order code Product Feature Operating voltage
3001 EMC Professional 3001 Active ferrite rod antenna (cable length 5 m) and
external power supply unit included in delivery
External power supply
unit (12 V)
3011 EMC Professional 3011 Active ferrite rod antenna included in delivery (cable
length 5 m)
230 V
7000 Temperature Sensor 7000 -20°C to +80°C
7901 Power Supply Unit 7901 12 V DC, 500 mA, plug for 2.1 mm pin
Features
• Reception of time and date based on DCF77 signal within a
2000 km radius around Frankfurt/Main
• Stand-alone NTP time server
• Battery buered and temperature compensated real time clock
• Signal monitor
• LC display for time and date
• Ideal reception through active ferrite rod antenna (included
in delivery)
• Switchable potential-free relay output (24 V, 0.5 A)
• 3011: Interface for optional temperature sensor
• Independent of OS (Ethernet, RS232)
• Firmware update via Ethernet during operation
• HTTP 1.1, DHCP, SNMPv1 (Traps), SNMPv2c (Traps), Syslog
• Access control via IP Access Control List
• Access control via optional HTTP password
• Low power consumption
• Developed and manufactured in Germany
Ordering Information
EMC Professional 3011
Electrical Connections
• DC socket for external power supply unit (3001)
• 1 power supply IEC C14 (3011)
• Ethernet connector RJ45 (10/100 Mbit/s)
• 1 switchable output (PTR multiconnector, 2-fold)
• RJ11 interface for optional temperature sensor (3011)
• Serial interface RS232 (Sub-D, 9-pin)
• BNC connector for active antenna
Technical Details
• LxHxD: 17 x 6.5 x 10.5 cm (3001)
• Weight: ca. 0.7 kg (3001)
• Dimensions: 19 inch, 1 rack unit (3011)
• Weight: ca. 2.2 kg (3011)
• Operating temperature: 0-50 °C (non-condensing
environment)
EMC Professional 3001