Radio Time Systems
EMC Professional 3001 / 3011
Order code Product Feature Operating voltage
3001 EMC Professional 3001 Active ferrite rod antenna (cable length 5 m) and
external power supply unit included in delivery
External power supply
unit (12 V)
3011 EMC Professional 3011 Active ferrite rod antenna included in delivery (cable
length 5 m)
230 V
7000 Temperature Sensor 7000 -20°C to +80°C
7901 Power Supply Unit 7901 12 V DC, 500 mA, plug for 2.1 mm pin
Features
Reception of time and date based on DCF77 signal within a
2000 km radius around Frankfurt/Main
Stand-alone NTP time server
Battery buered and temperature compensated real time clock
Signal monitor
LC display for time and date
Ideal reception through active ferrite rod antenna (included
in delivery)
Switchable potential-free relay output (24 V, 0.5 A)
3011: Interface for optional temperature sensor
Independent of OS (Ethernet, RS232)
Firmware update via Ethernet during operation
HTTP 1.1, DHCP, SNMPv1 (Traps), SNMPv2c (Traps), Syslog
Access control via IP Access Control List
Access control via optional HTTP password
Low power consumption
Developed and manufactured in Germany
Ordering Information
EMC Professional 3011
Electrical Connections
DC socket for external power supply unit (3001)
1 power supply IEC C14 (3011)
Ethernet connector RJ45 (10/100 Mbit/s)
1 switchable output (PTR multiconnector, 2-fold)
RJ11 interface for optional temperature sensor (3011)
Serial interface RS232 (Sub-D, 9-pin)
BNC connector for active antenna
Technical Details
LxHxD: 17 x 6.5 x 10.5 cm (3001)
Weight: ca. 0.7 kg (3001)
Dimensions: 19 inch, 1 rack unit (3011)
Weight: ca. 2.2 kg (3011)
Operating temperature: 0-50 °C (non-condensing
environment)
EMC Professional 3001