Measurement Parameters Menu
Depth defines the length of the radargram vertical scale. This is
sometimes referred to as the time window length. In this case,
the the set velocity is used to calculate the depth window.
Note: This value will vary if the soil velocity measurement
parameter is changed.
Set to manual or auto (Automatic Gain Control).
Note: Manual gain activates the Time Gain button on the main
screen and allows the user to manually adjust the gain. Selecting
Auto deactivates the Time Gain button on the main screen and the
GX HDR Controller will apply the highest gain level for the signal to
noise ratio.
Set the velocity based on soil type. Setting the velocity allows the
adjustment of the depth scale for differing soil conditions.
Warning: This is a critical setting if accurate depth information is
required. Soil conditions can vary rapidly with location and all
depth information must be used with caution.
Tip: The velocity can be set during the post-processing stage; it is
not critical that this measurement is established during the data
collection stages, unless marking the depth on site.
Set the type of trigger to be used for initiating a measurement.
Three triggering options are available:
Wheel, Time, or Keyboard Triggering.