MSDS
Gumout Jet Spray Carburetor and Choke Cleaner
MSDS# 600951LU
Version 3.0
Material Safety Data Sheet
Effective Date 5/4/2011
According to OSHA Hazard Communication Standard, 29 CFR
1910.1200
4/8
Print Date 05/04/2011 MSDS_US
Additional Information
: Adequate ventilation to control airborne concentrations below
the exposure
g
uidelines/limits.
Shell has adopted as Interim Standards the OSHA Z1A values
that were established in 1989 and later rescinded.
Exposure Controls
: Adequate ventilation to control airborne concentrations below
the exposure guidelines/limits.
Personal Protective
Equipment
: Personal protective equipment (PPE) should meet
recommended national standards. Check with PPE suppliers.
Respiratory Protection
: Check with respiratory protective equipment suppliers.
Hand Protection
: PVC, neoprene or nitrile rubber gloves.
Eye Protection
: Chemical splash goggles (chemical monogoggles).
Environmental Exposure
Controls
: Use only in well-ventilated areas.
9. PHYSICAL AND CHEMICAL PROPERTIES
Appearance : Colourless to yellowish. Aerosol. Liquid.
Odour : Alcohol-like.
pH : Not applicable
Initial Boiling Point and
Boiling Range
: 56 °C / 133 °F
Melting / freezing point : < 95 °C / 203 °F
Flash point : -20 °C / -4 °F (Tag Closed Cup (ASTM D56))
Upper / lower Flammability
or Explosion limits
: 2.6 - 12.8 %(V)
Auto-ignition temperature : 465 °C / 869 °F
Vapour pressure : 185 hPa at 20 °C / 68 °F
Specific gravity : 0.798
Density : 0.797 g/cm3 (ASTM D-4052)
Water solubility : Miscible.
n-octanol/water partition
coefficient (log Pow)
: 2.65
(based on active matter)
0.2 (based on active matter)
Kinematic viscosity : < 1 mm2/s at 40 °C / 104 °F
Volatility : 100 % vol
Volatile organic carbon
content
9.8 % vol
Evaporation rate (nBuAc=1) : 14.4
10. STABILITY AND REACTIVITY
Stability
: Stable under normal conditions of use.
Conditions to Avoid
: Open flame.
Materials to Avoid
: Not applicable.
Hazardous Decomposition
Products
: None expected under normal use conditions.
Hazardous Polymerisation
: No
Sensitivity to Mechanical
Impact
: No