User guide

- 10 -
will blink green five times. And you will hear five beeps, confirming that the new code has been
accepted. If the red light blinks 5 times with 5 beeps at this point, and error has occurred. Just start
over by depressing the Learn Button for two seconds.
5. Turning off Keypad Sound
To disable the Keypad Sound (beeps), press and hold the Learn Button for two seconds, three times.
The green light will blink three times and you will hear three beeps. Release the button. Then press
and hold buttons two and three for five seconds. The Keypad Sound is now disabled, but this does not
disable the alarm sound.
6. Tamper Detect Feature
Entering an invalid access code sets the tamper indicator.
Hold down buttons two and three for five seconds to read the tamper indicator.
If tampering has been detected, the red light will glow until buttons two and three are released.
If tampering has not been detected, the green light will glow until buttons two and three are
released.
7. Security Sleep Mode
The GunVault safe has a “Security Sleep Mode” that activates when 24 consecutive incorrect entries
are made (if the correct code is entered within 24 entries, the door will open). During Sleep Mode the
keypad does not accept any entries and last for two minutes. If a button is depressed during Sleep
Mode, the LED blinks red and the alarm beeps three times. The backup key may be used to open the
safe during sleep mode (HV3000).
8. Mounting the Safe (HV3000 only)
The Vault can be mounted in almost any direction.
Think carefully before you begin to drill holes;
make sure you could easily reach the keypad, but
protect the safe from children.
IMPORTANT: Do not mount the Vault with the
door facing down! The contents could fall out
when the door is opened!
Think about your own unique mounting requirements. You may wish to use washers, lag bolts, or
other mounting devices for reasons of your own.