7 DownloadingthedataintheLoggers
EnsuretheCommLink,antennaandPCconnectionsarecorrectlymadeandswitchtheCommlinkon.Click
theSynchronizebuttonandasmallerwindowappears.SeeFig.17.Todownloadtheloggers,beginby
selectingthebox;‘Getmeasurements’.
If‘TransferloggersettingsfromPCtologger
isselectedthenthiswillpreparetheloggersforthenextlogging
session,besuretoselecttheLoggersettingspriortoSynchronization.Thiswillcleartheloggermemoryonce
theloggerdatahasbeendownloaded.
Ifacorrelationisrequired,alsocheckthebox‘Getnoisesignalforcorrel
ation’asshown(Pleasenote:a
correlationsignalwillonlybeavailableiftheloggersweresettorecordacorrelationduringsynchronization
inthelast24hrs)

Fig.17download settings in theSynchronize window
Selectbox;“Synchronizeonlyreachableloggers”iftheloggersarestilldeployedinthefieldor‘Synchronize
accordingtolist’iftheloggersaretogetherintheircarrycase.
Synchronizationmodefor‘Getmeasurements’has2options1.Leakvaluesandlatestamplitudedistribution
(FastSy
nc)thisisusedfordownloadingtheresultsofthepreviousnightslogging.
Allavailableamplitudedistributionswhichdownloadsallavailablenightsrecordings,thisisusuallyrequiredif
theloggershavebeendeployedinthesamelocationforseveraldayswithoutbeingdownloaded.
Select‘Getsoundsignalforcorrelation’todown
loadtherecordedsoundsignalfromthepreviousnight
logging.Foraccuratecorrelationsdownloadrecordedsoundsignalswitha24hourperiod.
Important:PriortoSynchronizationsettheLeakThresholdLevelsforpossibleandprobableLeak,forthis
informationP.T.O.